Ururtm 1CHWF: Module Dead / Blown Fuse/SMPS
What this means: Module shows no signs of power (LED off, unresponsive) after initial wiring, or a connected fuse/breaker trips.
60-Second Verification Check
Confirm only ONE power source (either AC 100–240V OR DC 12V/24V) is connected to the correct terminals—never both simultaneously. Verify input voltage with a multimeter.
Verified Replacement Parts
Ururtm UR-1CHWF Complete Relay Module
Direct replacement for the original module.
Why This Happens & Safety Warnings
What triggers it: Simultaneous connection of both AC 100-240V and DC 12V/24V power inputs, or incorrect polarity on DC input.
What wears out inside: Applying incompatible or multiple power sources simultaneously overloads and damages the internal AC-DC SMPS and/or DC-DC buck regulator stages.
Symptom on machine: The module becomes completely inoperable ('dead'), with no power indicator or response. May also cause external fuses to blow or circuit breakers to trip.
Cross-Compatible Platforms: Shares Tuya-ecosystem micro-relay form factor with sibling Ururtm Wi-Fi models (UR-1CH-WF, UR-2CH-AC), differing in wireless protocol (Zigbee vs. Wi-Fi) and channel count.