FA // X-RAYFailureAtlas.orgComponent Triage & OEM MPN Index
HARDWARE SYMPTOM MODEL: 1CHWF TIER 1–2 BENCH DIY

Ururtm 1CHWF: Zigbee Pairing Failure

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

Status LED blinks continuously, but the Zigbee hub fails to discover or add the device to the network.

02 // Non-Invasive Meter / Bench Verification

Verify compatible Zigbee 3.0 coordinator (Tuya/Hubitat), move module within 3 meters of hub during pairing, and perform a factory reset via the tactile pairing button. Check hub logs for errors.

Platform / OEM Cross-Reference: Shares Tuya-ecosystem micro-relay form factor with sibling Ururtm Wi-Fi models (UR-1CH-WF, UR-2CH-AC), differing in wireless protocol (Zigbee vs. Wi-Fi) and channel count.

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Isolated Match
UR-1CHWF Ururtm UR-1CHWF Complete Relay Module
Direct replacement for the original module.
Retail varies (typical category $12–$25)
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified in wall micro relays dry contacts replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINNOMINAL ON SKU
MOD_02 // POWER & BMSFAULT IMPLICATED
MOD_03 // THERMALNOMINAL ON SKU
MOD_04 // FLUID & WATERNOMINAL ON SKU
MOD_05 // AIRFLOW & ACOUSTICNOMINAL ON SKU
MOD_06 // OPTICAL & SENSORFAULT IMPLICATED
MOD_07 // RF & SMART CTRLFAULT IMPLICATED
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:ABSBRASS

Failure Physics & Causal Isolation

Root Failure Mechanism: Zigbee Dropouts / Low Link Quality (LQI)Click to spotlight part ↑

01 // Trigger ConditionInstallation inside metal electrical boxes, excessive distance from the Zigbee hub, or high 2.4 GHz Wi-Fi channel overlap/interference.
02 // Degradation PhysicsRF signals are attenuated by metal enclosures or overwhelmed by co-channel interference, leading to reduced Link Quality Indicator (LQI) and increased packet loss.
03 // Lockout / ImpactThe module becomes unresponsive to commands, experiences delayed state changes, or drops off the Zigbee network entirely, disrupting automation.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Distinct single mechanical 'click' sound when the relay changes state (ON to OFF, or OFF to ON).: This is the normal acoustic signature of the electromechanical dry-contact relay's armature closing or opening, indicating successful switching. (True fault when: If the relay clicks but the load does not change state, or if the clicking is rapid/chattering without command, it may indicate a fault (e.g., welded contacts, insufficient coil voltage).)

Other Ururtm 1CHWF Diagnostic Sheets

Type at least 2 characters to search across all 10 HTC hardware divisions...