UNIT DOWN? Verified OEM & Aftermarket Fix Kit Below
Jump to Parts Kit ↓
EXPLICIT FAULT CODE MODEL: DD24STI9N

Fisher & Paykel DD24STI9N: A09 Fault Code

Observed Condition: Sanitize Temperature Not Met: Tripped if water temperature fails to sustain the mandatory 160°F sanitize holding window.

Immediate Non-Invasive Triage: Ensure incoming water temperature is adequate, check for interrupted cycles, or potential heater failure.

Platform Cross-Reference: Motorized Sealing Mechanism: Dual 24V DC micro-actuators drive worm gears and yokes to lower an internal sealing lid onto the drawer rim upon cycle start (shared across DishDrawer platform generations).

Verified Replacement Parts & Fix Kit

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Part # 524922P SmartDrive Motor Rotor Assembly
Must verify rotor magnet clearance and impeller housing O-ring condition during replacement.
~$80 - $120 (est.)
Part 2
oem replacement part
Motorized Lid Actuator… Motorized Lid Actuator Assembly
Often replaced when nylon drive gear shears or motor stalls (Error F51).
~$95 - $150 (est.)
Replace Unit DROP-IN SPEC Repair Exceeds Appliance Value?
Compare verified integrated single tall dishdrawer dishwasher replacements & cutout specs.
Compare See Top Replacements →

Failure Physics & Technician Isolation

Safety & Disassembly Warnings:
  • All internal repairs, including disassembly of the base chassis or removal of internal wiring, are explicitly restricted to authorized technicians due to electrical shock and high-temperature scald hazards.

Root Mechanism: Sanitize Temperature Not Met

Trigger: Interrupted cycle, low incoming water temperature, or heater failure.

Physics / Degradation: The water temperature fails to sustain the mandatory 160°F sanitize holding window.

System Lockout / Impact: Sanitize cycle fails to meet hygienic criteria, dishes may not be fully sanitized.

Before Ordering Parts: Normal Behavior vs. True Fault

False-Alarm Check — Knock to Pause Sensor Non-Responsive: Acoustic vibration from external knuckle strike is dissipated by excessive wood mass or flexible silicone adhesives, failing to trigger the internal piezoelectric sensor threshold. This is often due to heavy or thick custom wood panels. (True fault when: If the sensor is unresponsive even with a light custom panel or no panel, or if it stops working after a period of normal operation, it may indicate a sensor or control board fault.)

Other Fisher & Paykel DD24STI9N Fault Signals