Fisher & Paykel DD24STI9N: F51 Fault Code

Observed Condition: Lid Actuator Jam / Failure to Lower: Motorized lid assembly fails to descend and seal the tub.

Immediate Non-Invasive Triage: Check for tall dishes or utensils obstructing lid path; inspect actuator for physical damage.

Platform Cross-Reference: Motorized Sealing Mechanism: Dual 24V DC micro-actuators drive worm gears and yokes to lower an internal sealing lid onto the drawer rim upon cycle start (shared across DishDrawer platform generations).

Verified Replacement Parts & Fix Kit

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Motorized Lid Actuator… Motorized Lid Actuator Assembly
Often replaced when nylon drive gear shears or motor stalls (Error F51).
~$95 - $150 (est.)
Replace Unit DROP-IN SPEC Repair Exceeds Appliance Value?
Compare verified integrated single tall dishdrawer dishwasher replacements & cutout specs.
Compare See Top Replacements →

Failure Physics & Technician Isolation

Safety & Disassembly Warnings:
  • All internal repairs, including disassembly of the base chassis or removal of internal wiring, are explicitly restricted to authorized technicians due to electrical shock and high-temperature scald hazards.

Root Mechanism: Lid Actuator Gearbox Stripping / Jam

Trigger: Tall dishes or utensils protruding above tub rim during drawer closure.

Physics / Degradation: When dishes block the descending lid, the DC motor encounters stall resistance. Repeated obstruction strips small nylon planetary gears, causing lid motor stall.

System Lockout / Impact: Dishwasher fails to start cycle (F51 error), lid remains open, dishes are not washed.

Before Ordering Parts: Normal Behavior vs. True Fault

False-Alarm Check — Knock to Pause Sensor Non-Responsive: Acoustic vibration from external knuckle strike is dissipated by excessive wood mass or flexible silicone adhesives, failing to trigger the internal piezoelectric sensor threshold. This is often due to heavy or thick custom wood panels. (True fault when: If the sensor is unresponsive even with a light custom panel or no panel, or if it stops working after a period of normal operation, it may indicate a sensor or control board fault.)

Other Fisher & Paykel DD24STI9N Fault Signals