EXPLICIT FAULT CODE MODEL: DD24STI9N

Fisher & Paykel DD24STI9N: F1 Fault Code

Observed Condition: Flood Condition Detected: Water pooling in the lower chassis drip tray. Triggers emergency pump operation; dishwasher continuously beeps and drains until power is disconnected.

Immediate Non-Invasive Triage: Inspect for visible leaks, check lid seal for debris, verify sump O-ring integrity.

Platform Cross-Reference: Motorized Sealing Mechanism: Dual 24V DC micro-actuators drive worm gears and yokes to lower an internal sealing lid onto the drawer rim upon cycle start (shared across DishDrawer platform generations).

Verified Replacement Parts & Fix Kit

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Part # 524922P SmartDrive Motor Rotor Assembly
Must verify rotor magnet clearance and impeller housing O-ring condition during replacement.
~$80 - $120 (est.)
Part 2
oem replacement part
Motorized Lid Actuator… Motorized Lid Actuator Assembly
Often replaced when nylon drive gear shears or motor stalls (Error F51).
~$95 - $150 (est.)
Replace Unit DROP-IN SPEC Repair Exceeds Appliance Value?
Compare verified integrated single tall dishdrawer dishwasher replacements & cutout specs.
Compare See Top Replacements →

Failure Physics & Technician Isolation

Safety & Disassembly Warnings:
  • All internal repairs, including disassembly of the base chassis or removal of internal wiring, are explicitly restricted to authorized technicians due to electrical shock and high-temperature scald hazards.

Root Mechanism: Base Pan Flood Trip from Gasket Bypass

Trigger: Mineral/detergent crust on tub rim, aging/degraded lid gasket, or split sump O-ring.

Physics / Degradation: Water escapes over the front or side lip during high-pressure wash cycles, dripping into the enclosed base pan. The polystyrene float activates the F1 emergency flood shutoff.

System Lockout / Impact: Dishwasher halts operation entirely, continuously drains, and beeps, requiring manual intervention and leak source identification.

Before Ordering Parts: Normal Behavior vs. True Fault

False-Alarm Check — Knock to Pause Sensor Non-Responsive: Acoustic vibration from external knuckle strike is dissipated by excessive wood mass or flexible silicone adhesives, failing to trigger the internal piezoelectric sensor threshold. This is often due to heavy or thick custom wood panels. (True fault when: If the sensor is unresponsive even with a light custom panel or no panel, or if it stops working after a period of normal operation, it may indicate a sensor or control board fault.)

Other Fisher & Paykel DD24STI9N Fault Signals