HARDWARE SYMPTOM MODEL: F-18DP

Jet-Tech F-18DP: Machine fails to drain or drain cycle exceeds 2 minutes

Observed Condition: Soiled wash water remains standing in the 7.25-gallon sump after pulling the overflow standpipe and initiating the motorized drain sequence.

Immediate Non-Invasive Triage: Verify the overflow standpipe was removed for draining; inspect the 1-inch ID rear discharge hose for kinks or vertical routing above the 36-inch lift limit; check scrap screens and sump drain intake for broken glass, toothpicks, or debris.

Platform Cross-Reference: Operator manuals cover F-14, F-16DP, F-18DP, and F-22 concurrently; 120 V / 12.9-13.5 A ratings belong to compact F-14/F-16DP glasswashers and do not apply to F-18DP.

Verified Replacement Parts & Fix Kit

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
OEM #20711 Motorized Drain Discharge Pump Assembly (100 W)
Exact SKU OEM catalog verification (#20711); specific to 'DP' pumped-drain configuration (do not substitute gravity-drain kits).
$1,761.24 CAD MSRP list
Replace Unit DROP-IN SPEC Repair Exceeds Appliance Value?
Compare verified undercounter high temp commercial dishwasher replacements & cutout specs.
Compare See Top Replacements →

Failure Physics & Technician Isolation

Safety & Disassembly Warnings:
  • Disconnect main 208-240 V electrical power at the facility circuit breaker before removing the top, rear, or lower protective service panels.
  • Shut off incoming hot water supply, drain the system, and allow the pressurized 185-194°F rinse booster boiler to cool completely before servicing heating elements or temperature probes to prevent severe thermal scalding.

Root Mechanism: Motorized Drain Pump Impeller Jamming or Motor Burnout

Trigger: Operating with unseated or damaged scrap screens, allowing broken glass, toothpicks, or straws into the drain sump, or routing the 1-inch ID drain hose above the 36-inch vertical lift limit.

Physics / Degradation: Foreign debris bypasses filtration and wedges between the pump housing and impeller of the 100 W drain pump (#20711), or excessive head backpressure (>36 in lift) stalls evacuation, locking the rotor and overheating the 100 W motor windings.

System Lockout / Impact: Inability to evacuate soiled wash water at shift end; if the motor burns out, OEM replacement assembly #20711 carries a high list price (~$1,761.24 CAD).

Before Ordering Parts: Normal Behavior vs. True Fault

False-Alarm Check — The 2,800 W wash tank immersion heater shuts off whenever the 4,000 W rinse booster heater is actively heating.: The F-18DP uses a non-simultaneous alternating electrical contactor interlock that gives absolute priority to the 4.0 kW booster heater so total machine current draw stays within 22.0-23.5 A on a 30 A single-phase circuit. (True fault when: Indicates a fault only if the wash tank temperature drops significantly below 150°F and the wash element fails to re-energize after the booster tank has satisfied its 185-194°F thermostat setpoint.)
False-Alarm Check — Absence of a perimeter rubber door gasket and minor steam wisps or occasional water droplets around the front drop-down door channel during wash cycles.: The F-18DP utilizes a commercial sanitary labyrinth door baffle design that intentionally eliminates synthetic perimeter door gaskets to prevent bacterial harboring and elastomer degradation. (True fault when: Indicates a fault if water actively pours out of the door base due to a clogged pneumatic air trap (#16666) causing sump overfill, an unlevel chassis, or bent door hinges (#15562).)

Other Jet-Tech F-18DP Fault Signals