UNIT DOWN? Verified OEM & Aftermarket Fix Kit Below
Jump to Parts Kit ↓
HARDWARE SYMPTOM MODEL: F-18DP

Jet-Tech F-18DP: Persistent water spotting, filming, or grease residue on ware despite normal temperatures

Observed Condition: Ware exits the 160-second cycle with food residue or fails to sheet-dry cleanly despite wash (150°F) and rinse (185-194°F) temperatures meeting specification.

Immediate Non-Invasive Triage: Verify external detergent and rinse-aid supply containers are not empty and intake foot filters are submerged and unobstructed; check for air bubbles in pickup lines or chemical leaks behind the lower front kick panel.

Platform Cross-Reference: Operator manuals cover F-14, F-16DP, F-18DP, and F-22 concurrently; 120 V / 12.9-13.5 A ratings belong to compact F-14/F-16DP glasswashers and do not apply to F-18DP.

Verified Replacement Parts & Fix Kit

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
routine consumable
Universal Santoprene… Peristaltic Chemical Pump Santoprene Squeeze Tube Kit
Compatible with sodium/potassium hydroxide detergent and surfactant rinse aid; wear chemical PPE during replacement.
~$25-$45 USD
Replace Unit DROP-IN SPEC Repair Exceeds Appliance Value?
Compare verified undercounter high temp commercial dishwasher replacements & cutout specs.
Compare See Top Replacements →

Failure Physics & Technician Isolation

Safety & Disassembly Warnings:
  • Disconnect main 208-240 V electrical power at the facility circuit breaker before removing the top, rear, or lower protective service panels.
  • Shut off incoming hot water supply, drain the system, and allow the pressurized 185-194°F rinse booster boiler to cool completely before servicing heating elements or temperature probes to prevent severe thermal scalding.

Root Mechanism: Peristaltic Chemical Pump Squeeze Tube Compression Fatigue and Rupture

Trigger: Cumulative cycle operation compressing the Santoprene squeeze tubes against the motorized pump rollers in contact with caustic pH 11 detergent and rinse aid.

Physics / Degradation: Cyclic elastomeric compression causes wall flattening (loss of suction rebound) followed by longitudinal fatigue cracking of the Santoprene tube.

System Lockout / Impact: Loss of automatic detergent or rinse-aid injection (resulting in greasy or spotted ware) and potential dripping of caustic hydroxide chemical inside the lower front service bay. Squeeze tubes are excluded from warranty as wear items.

Before Ordering Parts: Normal Behavior vs. True Fault

False-Alarm Check — The 2,800 W wash tank immersion heater shuts off whenever the 4,000 W rinse booster heater is actively heating.: The F-18DP uses a non-simultaneous alternating electrical contactor interlock that gives absolute priority to the 4.0 kW booster heater so total machine current draw stays within 22.0-23.5 A on a 30 A single-phase circuit. (True fault when: Indicates a fault only if the wash tank temperature drops significantly below 150°F and the wash element fails to re-energize after the booster tank has satisfied its 185-194°F thermostat setpoint.)
False-Alarm Check — Absence of a perimeter rubber door gasket and minor steam wisps or occasional water droplets around the front drop-down door channel during wash cycles.: The F-18DP utilizes a commercial sanitary labyrinth door baffle design that intentionally eliminates synthetic perimeter door gaskets to prevent bacterial harboring and elastomer degradation. (True fault when: Indicates a fault if water actively pours out of the door base due to a clogged pneumatic air trap (#16666) causing sump overfill, an unlevel chassis, or bent door hinges (#15562).)

Other Jet-Tech F-18DP Fault Signals