Observed Condition: Water continues entering the wash sump past the normal level or overflows out the front door channel when the unit is idle or running.
Immediate Non-Invasive Triage: Confirm the overflow standpipe is properly seated; shut off main power to test if filling stops (if water continues flowing with power off, the inlet solenoid valve #20569 is mechanically stuck open; if it stops when power is cut, the pneumatic air trap #16666 or pressure switch #16345 is failing to signal full level).
Platform Cross-Reference: Operator manuals cover F-14, F-16DP, F-18DP, and F-22 concurrently; 120 V / 12.9-13.5 A ratings belong to compact F-14/F-16DP glasswashers and do not apply to F-18DP.
| Role | OEM MPN / Spec | Component & Fitment Notes | Est. Street | Check Stock |
|---|---|---|---|---|
| Part 1 oem replacement part |
OEM Switch #16345 | Pneumatic Diaphragm Water Level Pressure Switch & Air Trap Factory parts list verification (#16345, #16666); always clear air trap #16666 and tubing of grease/scale before replacing switch. |
~$60-$95 USD | |
| Part 2 oem replacement part |
OEM #20569 | Water Inlet Solenoid Valve (240 V, 60 Hz, 3/4-inch NPT) Factory parts list verification (#20569); confirm 240 V coil rating and isolate water/electrical supplies prior to replacement. |
~$75-$120 USD | |
| Replace Unit | DROP-IN SPEC | Repair Exceeds Appliance Value? Compare verified undercounter high temp commercial dishwasher replacements & cutout specs. |
Compare | See Top Replacements → |
Trigger: Accumulation of food grease, organic slime, or mineral scale inside the wash sump due to skipped daily draining/flushing or hard water.
Physics / Degradation: Debris and solidified grease obstruct the narrow stainless steel pneumatic air trap dome (#16666) or connecting tube, preventing rising sump water from compressing the trapped air column needed to actuate diaphragm pressure switch #16345.
System Lockout / Impact: The control circuit fails to register a full tank and keeps the 240 V water inlet solenoid valve (#20569) energized, flooding the wash sump and overflowing onto the kitchen floor.