UNIT DOWN? Verified OEM & Aftermarket Fix Kit Below
Jump to Parts Kit ↓
EXPLICIT FAULT CODE MODEL: 22-14782

Kenmore 22-14782: E3

Observed Condition: Water Heating Timeout: Water fails to reach targeted temperature rise within calibrated duration (~9 min).

Immediate Non-Invasive Triage: Verify incoming hot water temperature (env_02_water_temperature), check for mineral scale on element (maint_03_tub_descaling), test heating element continuity with multimeter.

Platform Cross-Reference: Platform Mechanical Twin: Midea MDF24P series (MDF24P1BWW, MDF24P2BWW, CDW2FCMW)

Verified Replacement Parts & Fix Kit

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Midea 120 V calrod… Immersion Calrod Heating Element
Always replace bottom basin silicone sealing washers when installing element.
~$45–$85
Part 2
oem replacement part
40514782420 High-Limit Safety Thermostat
Clips to the underside exterior floor of the molded polypropylene basin.
~$18–$30
Replace Unit DROP-IN SPEC Repair Exceeds Appliance Value?
Compare verified undercounter built in automatic residential dishwasher replacements & cutout specs.
Compare See Top Replacements →

Failure Physics & Technician Isolation

Safety & Disassembly Warnings:
  • The perimeter interface between the stainless steel tub walls and the polypropylene bottom basin is a factory-crimped, permanently sealed structural joint. No field repair procedures, gasket replacement kits, or mechanical re-crimping tools are provisioned for this joint; any compromise or fluid breach along this multi-material boundary necessitates replacement of the complete tub assembly or scrapping the appliance.
  • The internal bearing and stator windings of the permanent magnet wash pump are hermetically sealed, preventing sub-component rebuilding and requiring complete pump replacement upon mechanical failure.

Root Mechanism: Calrod Heating Element Burnout from Hard Water Scaling

Trigger: Hard water scaling (water hardness >7 GPG) and prolonged thermal cycles

Physics / Degradation: Heavy calcium carbonate deposition forms an insulating blanket over the element sheath, causing internal coil overheating and open-circuit burnout.

System Lockout / Impact: Water heating timeout (Error E3), cold wash cycles, ineffective heated dry, unit inoperable.

Before Ordering Parts: Normal Behavior vs. True Fault

False-Alarm Check — Initial High-Heat Odor (Mastic Curing): Thermal curing of bituminous asphaltic mastic pads and manufacturing coatings on the new calrod heating element. (True fault when: If the odor persists beyond 5 high-temperature sanitizing wash cycles or is accompanied by smoke/burning smells.)
False-Alarm Check — Incomplete Plasticware Moisture Removal: Physical property of plastics having low thermal mass and high water surface tension, combined with static heated dry mechanics. (True fault when: If ceramic or glass items are also consistently wet, or if rinse aid is being used correctly and the Heated Dry option is selected.)

Other Kenmore 22-14782 Fault Signals