EXPLICIT FAULT CODE MODEL: 22-14782

Kenmore 22-14782: E4

Observed Condition: Anti-Flood Alarm / Leak Detected: Accumulated liquid in bottom drip tray elevates polystyrene float switch.

Immediate Non-Invasive Triage: Inspect for visible leaks under the dishwasher, check for excessive sudsing (due to incorrect detergent), verify door seal integrity (maint_04_door_gasket_care). Safety interlock immediately disables inlet valve and continuously energizes drain pump.

Platform Cross-Reference: Platform Mechanical Twin: Midea MDF24P series (MDF24P1BWW, MDF24P2BWW, CDW2FCMW)

Verified Replacement Parts & Fix Kit

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
11001011002369 Permanent Magnet Wash Pump
OEM P/N 11001011002369 is confirmed for Kenmore 405.14782420 and Midea platforms. Verify terminal connector orientation.
~$95–$140
Part 2
oem replacement part
Midea platform… Dedicated Drain Pump Motor
Coil winding resistance should measure between 220 Ω and 250 Ω.
~$35–$65
Replace Unit DROP-IN SPEC Repair Exceeds Appliance Value?
Compare verified undercounter built in automatic residential dishwasher replacements & cutout specs.
Compare See Top Replacements →

Failure Physics & Technician Isolation

Safety & Disassembly Warnings:
  • The perimeter interface between the stainless steel tub walls and the polypropylene bottom basin is a factory-crimped, permanently sealed structural joint. No field repair procedures, gasket replacement kits, or mechanical re-crimping tools are provisioned for this joint; any compromise or fluid breach along this multi-material boundary necessitates replacement of the complete tub assembly or scrapping the appliance.
  • The internal bearing and stator windings of the permanent magnet wash pump are hermetically sealed, preventing sub-component rebuilding and requiring complete pump replacement upon mechanical failure.

Root Mechanism: Base Drip Tray Flooding and Anti-Flood Alarm Trip

Trigger: Internal hose weeping, door seal breach, or excessive sudsing from incorrect detergent

Physics / Degradation: Slow leaks or excessive foam accumulate in the bottom pan, lifting the polystyrene float disc and tripping the anti-flood safety lock.

System Lockout / Impact: Anti-flood alarm (Error E4), unit immediately stops operation and continuously drains, potential kitchen floor damage.

Root Mechanism: Hybrid Tub Multi-Material Mechanical Joint Weeping

Trigger: Long-term differential thermal expansion cycling between steel and plastic

Physics / Degradation: Repeated thermal cycling induces differential strain, eventually fatiguing the factory-crimped perimeter gasket.

System Lockout / Impact: Micro-weeping at perimeter joint, leading to base drip tray flooding (Error E4) and unit shutdown.

Before Ordering Parts: Normal Behavior vs. True Fault

False-Alarm Check — Initial High-Heat Odor (Mastic Curing): Thermal curing of bituminous asphaltic mastic pads and manufacturing coatings on the new calrod heating element. (True fault when: If the odor persists beyond 5 high-temperature sanitizing wash cycles or is accompanied by smoke/burning smells.)
False-Alarm Check — Incomplete Plasticware Moisture Removal: Physical property of plastics having low thermal mass and high water surface tension, combined with static heated dry mechanics. (True fault when: If ceramic or glass items are also consistently wet, or if rinse aid is being used correctly and the Heated Dry option is selected.)

Other Kenmore 22-14782 Fault Signals