Observed Condition: NTC Thermistor Open / Short: Microcontroller detects open circuit (E6) or short circuit (E7) across NTC lines.
Immediate Non-Invasive Triage: Test NTC thermistor resistance with multimeter. Machine terminates heating cycle immediately to prevent thermal runaway.
Platform Cross-Reference: Platform Mechanical Twin: Midea MDF24P series (MDF24P1BWW, MDF24P2BWW, CDW2FCMW)
| Role | OEM MPN / Spec | Component & Fitment Notes | Est. Street | Check Stock |
|---|---|---|---|---|
| Part 1 oem replacement part |
11001011002369 | Permanent Magnet Wash Pump OEM P/N 11001011002369 is confirmed for Kenmore 405.14782420 and Midea platforms. Verify terminal connector orientation. |
~$95–$140 | |
| Part 2 oem replacement part |
Midea platform… | Dedicated Drain Pump Motor Coil winding resistance should measure between 220 Ω and 250 Ω. |
~$35–$65 | |
| Replace Unit | DROP-IN SPEC | Repair Exceeds Appliance Value? Compare verified undercounter built in automatic residential dishwasher replacements & cutout specs. |
Compare | See Top Replacements → |