01 // Observed Condition

The 6-prong actuator star (KP66000) exhibits structural play or a cracked central spider web, preventing downward force and 1/8-turn rotation from unseating the nozzle valve.

02 // Non-Invasive Meter / Bench Verification

Shut off the under-sink water stop, pull the actuator pad vertically upward off the nozzle without tools, and inspect the underside central polymer spider webbing and locating tabs for cracks.

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Isolated Match
KP66000 Actuator Pad Assembly (Part A)
Exact OEM 6-prong silicone-overmolded actuator star cataloged in the Kraus KGR-500 installation manual.
$10–$20 est.
Part 2
oem replacement part
Isolated Match
KP66001 Rinsing Nozzle Head (Part B)
Exact OEM 9-orifice spray head core cataloged in the Kraus KGR-500 installation manual.
Check Live Stock
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified deck mounted glass and vessel rinsers replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINFAULT IMPLICATED
MOD_02 // POWER & BMSNOMINAL ON SKU
MOD_03 // THERMALINACTIVE
MOD_04 // FLUID & WATERFAULT IMPLICATED
MOD_05 // AIRFLOW & ACOUSTICFAULT IMPLICATED
MOD_06 // OPTICAL & SENSORNOMINAL ON SKU
MOD_07 // RF & SMART CTRLNOMINAL ON SKU
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:ABSBRASSSiliconeStainless Steel

Failure Physics & Causal Isolation

Safety & Disassembly Lockouts:
  • Always shut off the under-sink domestic water supply angle stop valve before removing the 6-prong actuator pad assembly (KP66000) to prevent accidental valve depression and pressurized vertical spraying.
  • Pull the actuator pad vertically straight upward during removal; do not pull laterally, which risks snapping the molded locating guides.

Root Failure Mechanism: Center Actuator Support Spider Fatigue Fracture Under Cyclic Pressing LoadClick to spotlight part ↑

01 // Trigger ConditionRepeated downward compression and 1/8-turn rotational twisting of drinkware against the 6-prong actuator star, or lateral pulling during cleaning removal.
02 // Degradation PhysicsCyclic mechanical bending and torsional stress across the central molded ABS spider hub induces fatigue cracking or snaps the locating guides.
03 // Lockout / ImpactActuator star collapses or detaches and can no longer depress and twist the nozzle valve, rendering the rinser inoperable until KP66000 is replaced.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Pressing straight down on the 6-prong actuator star without rotating does not discharge water.: The KGR-500MB incorporates a mandatory 1/8-turn rotational safety lock alongside downward compression to prevent accidental vertical spraying when no vessel is inverted over the nozzle. (True fault when: Indicates a fault only if applying simultaneous downward pressure and a 1/8-turn rotation with an open under-sink angle stop still fails to unseat the valve or if the central actuator spider is cracked.)
False-Alarm Check — Unit dispenses cold or tepid water during short 2-to-5-second glass rinsing bursts even when plumbed into the domestic hot water angle stop.: The unit has no active heater; standing water in the un-recirculated supply pipe ('dead-leg') and 42-inch hose cools to ambient room temperature between uses and must be purged before hot water reaches the nozzle. (True fault when: Not a product fault; running the main kitchen hot faucet beforehand purges the cold dead-leg so hot water reaches the branch tee immediately.)