FA // X-RAYFailureAtlas.orgComponent Triage & OEM MPN Index
HARDWARE SYMPTOM MODEL: KGR-500MB TIER 1–2 BENCH DIY

KRAUS KGR-500MB: Deck base tray spins on countertop and drainage lip swings away from sink bowl

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

The entire upper base tray (KP66003) and mounting shank (KP66002) rotate out of alignment during under-sink locknut tightening or during repeated 1/8-turn safety lock operation.

02 // Non-Invasive Meter / Bench Verification

Check rotational play of the base tray by hand above the deck and inspect under-sink Mounting Nut (KP66005) clamping tension while a second person holds the top tray aligned over the basin.

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Isolated Match
KP66002 Mounting Shank (Part C)
Exact OEM 1 1/8-inch externally threaded ABS mounting shank with integrated quick-connect base receiver cataloged in the KGR-500 manual.
Check Live Stock
Part 2
oem replacement part
Isolated Match
KP66003 Base / Basin Tray (Part D)
Exact OEM sloped ABS drainage tray in Matte Black cataloged in the KGR-500 manual.
Check Live Stock
Part 3
oem replacement part
Isolated Match
KP66005 Mounting Nut (Part F)
Exact OEM under-counter retaining locknut fitting the 1 1/8-inch Mounting Shank (KP66002).
Check Live Stock
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified deck mounted glass and vessel rinsers replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINFAULT IMPLICATED
MOD_02 // POWER & BMSFAULT IMPLICATED
MOD_03 // THERMALINACTIVE
MOD_04 // FLUID & WATERFAULT IMPLICATED
MOD_05 // AIRFLOW & ACOUSTICNOMINAL ON SKU
MOD_06 // OPTICAL & SENSORNOMINAL ON SKU
MOD_07 // RF & SMART CTRLNOMINAL ON SKU
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:ABSBRASSSiliconeStainless Steel

Failure Physics & Causal Isolation

Safety & Disassembly Lockouts:
  • Always shut off the under-sink domestic water supply angle stop valve before removing the 6-prong actuator pad assembly (KP66000) to prevent accidental valve depression and pressurized vertical spraying.
  • Pull the actuator pad vertically straight upward during removal; do not pull laterally, which risks snapping the molded locating guides.

Root Failure Mechanism: Deck Base Rotation and Drainage Spout Misalignment from 1/8-Turn Actuation TorqueClick to spotlight part ↑

01 // Trigger ConditionSingle-person tightening of the under-sink mounting nut during installation, followed by repetitive 1/8-turn rotational twisting torque applied during every vessel rinse cycle.
02 // Degradation PhysicsRotational shear overcomes clamping friction between the smooth ABS base tray/gasket and polished stone or stainless sink decks, gradually loosening Mounting Nut (KP66005) and rotating Mounting Shank (KP66002).
03 // Lockout / ImpactForward drainage snout rotates away from the sink basin edge, directing dirty rinse runoff onto the countertop or allowing moisture seepage beneath the base.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Pressing straight down on the 6-prong actuator star without rotating does not discharge water.: The KGR-500MB incorporates a mandatory 1/8-turn rotational safety lock alongside downward compression to prevent accidental vertical spraying when no vessel is inverted over the nozzle. (True fault when: Indicates a fault only if applying simultaneous downward pressure and a 1/8-turn rotation with an open under-sink angle stop still fails to unseat the valve or if the central actuator spider is cracked.)
False-Alarm Check — Unit dispenses cold or tepid water during short 2-to-5-second glass rinsing bursts even when plumbed into the domestic hot water angle stop.: The unit has no active heater; standing water in the un-recirculated supply pipe ('dead-leg') and 42-inch hose cools to ambient room temperature between uses and must be purged before hot water reaches the nozzle. (True fault when: Not a product fault; running the main kitchen hot faucet beforehand purges the cold dead-leg so hot water reaches the branch tee immediately.)

Other KRAUS KGR-500MB Diagnostic Sheets

Type at least 2 characters to search across all 10 HTC hardware divisions...