FA // X-RAYFailureAtlas.orgComponent Triage & OEM MPN Index
HARDWARE SYMPTOM MODEL: KGR-500MB TIER 1–2 BENCH DIY

KRAUS KGR-500MB: Nozzle continues trickling after release or activates spray without vessel depression

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

Water continues to weep or discharge from the spray head after removing the vessel, indicating the internal spring-return poppet valve failed to seat completely.

02 // Non-Invasive Meter / Bench Verification

Immediately shut off the under-sink angle stop valve, remove the exterior actuator pad (KP66000) to verify it is not mechanically binding in the 1/8-turn rotated position, and contact Kraus support if internal valve leakage persists.

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Isolated Match
KP66001 Rinsing Nozzle Head (Part B)
Exact OEM 9-orifice spray head core cataloged in the Kraus KGR-500 installation manual.
Check Live Stock
Part 2
oem replacement part
Isolated Match
KP66002 Mounting Shank (Part C)
Exact OEM 1 1/8-inch externally threaded ABS mounting shank with integrated quick-connect base receiver cataloged in the KGR-500 manual.
Check Live Stock
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified deck mounted glass and vessel rinsers replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINFAULT IMPLICATED
MOD_02 // POWER & BMSNOMINAL ON SKU
MOD_03 // THERMALINACTIVE
MOD_04 // FLUID & WATERFAULT IMPLICATED
MOD_05 // AIRFLOW & ACOUSTICFAULT IMPLICATED
MOD_06 // OPTICAL & SENSORFAULT IMPLICATED
MOD_07 // RF & SMART CTRLNOMINAL ON SKU
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:ABSBRASSSiliconeStainless Steel

Failure Physics & Causal Isolation

Safety & Disassembly Lockouts:
  • Always shut off the under-sink domestic water supply angle stop valve before removing the 6-prong actuator pad assembly (KP66000) to prevent accidental valve depression and pressurized vertical spraying.
  • Pull the actuator pad vertically straight upward during removal; do not pull laterally, which risks snapping the molded locating guides.

Root Failure Mechanism: Internal Poppet Valve Seal Hang-Up, Weeping, or Unintended SprayingClick to spotlight part ↑

01 // Trigger ConditionParticulate sediment ingress from municipal water lines, mineral scale accumulation on sliding guides, or return spring/elastomeric seal fatigue under continuous line pressure.
02 // Degradation PhysicsDebris lodges between the elastomeric poppet seal and valve seat or mineral scale binds the sliding stem, preventing the internal stainless return spring from achieving a zero-leak shutoff.
03 // Lockout / ImpactContinuous water trickling down the tray or uncommanded vertical spraying into the kitchen until the under-sink angle stop is closed and the upper nozzle/shank assembly is replaced.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Pressing straight down on the 6-prong actuator star without rotating does not discharge water.: The KGR-500MB incorporates a mandatory 1/8-turn rotational safety lock alongside downward compression to prevent accidental vertical spraying when no vessel is inverted over the nozzle. (True fault when: Indicates a fault only if applying simultaneous downward pressure and a 1/8-turn rotation with an open under-sink angle stop still fails to unseat the valve or if the central actuator spider is cracked.)
False-Alarm Check — Unit dispenses cold or tepid water during short 2-to-5-second glass rinsing bursts even when plumbed into the domestic hot water angle stop.: The unit has no active heater; standing water in the un-recirculated supply pipe ('dead-leg') and 42-inch hose cools to ambient room temperature between uses and must be purged before hot water reaches the nozzle. (True fault when: Not a product fault; running the main kitchen hot faucet beforehand purges the cold dead-leg so hot water reaches the branch tee immediately.)

Other KRAUS KGR-500MB Diagnostic Sheets