HARDWARE SYMPTOM MODEL: FS3

FloodStop by OnSite PRO™ FS3: Continuous rapid beeping + rapid flashing red LED + valves closed

Observed Condition: Indicates the wired leak sensor (XS-01) has detected moisture.

Immediate Non-Invasive Triage: Press Mute, inspect for leak, dry both sides of sensor thoroughly, air dry, then press Open.

Platform Cross-Reference: Low-battery 4.2V threshold, 45–60 sec blink/beep diagnostics, older black wall-adapter troubleshooting, and extension wire compatibility apply across the entire FloodStop v4 product family.

Verified Replacement Parts & Fix Kit

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
XS-01 Extra / Replacement Wired Water Sensor Pad
Proprietary 2-prong snap connector requires OEM or compatible part.
~$39.21 (OEM street)
Part 2
routine consumable
Single layer of clean dry… Sensor Dielectric Paper Sleeve
Manual explicitly approves a standard paper towel as a substitute.
<$0.05
Replace Unit DROP-IN SPEC Repair Exceeds Appliance Value?
Compare verified Smart Washer Flood & Shutoff Valves replacements & cutout specs.
Compare See Top Replacements →

Failure Physics & Technician Isolation

Safety & Disassembly Warnings:
  • Do not use tools on manual override plastic gear.
  • Do not grip plastic motor drive housing for wrench leverage.

Root Mechanism: False Leak Triggers on Bare Metal / Damp Concrete

Trigger: Sensor placed on bare metal drain pan, damp concrete, or in high humidity environment.

Physics / Degradation: Missing or saturated paper sleeve, or high ambient conductivity, bridges double-sided sensor traces.

System Lockout / Impact: Nuisance shutoff of water supply and continuous alarm.

Before Ordering Parts: Normal Behavior vs. True Fault

False-Alarm Check — Solid green LED above Open/Close (AC power) OR blinking green LED every 45–60 sec (battery-only).: Solid green indicates AC power is connected. Blinking green every 45–60 seconds (without a beep) is the normal power-saving status indication when running on battery-only mode. (True fault when: If the blinking is accompanied by a short beep every 45-60 seconds, it indicates a low battery warning.)
False-Alarm Check — Brief motor whirring sound once every 30 days.: This is the scheduled 30-day automatic close/open anti-seize cycle, a normal self-maintenance function programmed into the v4 controller to prevent mineral scale buildup. (True fault when: If the motor runs continuously without actuating the valve, or if it occurs more frequently than monthly, it may indicate a fault.)

Other FloodStop by OnSite PRO™ FS3 Fault Signals