Observed Condition: Residual moisture on sensor, bare metal/sweating concrete contact, high sensitivity, or failing wall adapter.
Immediate Non-Invasive Triage: Place paper sleeve/towel on sensor, lower sensitivity setting, or test with sensor unplugged; if persistent, replace 9 VDC wall adapter.
Platform Cross-Reference: Low-battery 4.2V threshold, 45–60 sec blink/beep diagnostics, older black wall-adapter troubleshooting, and extension wire compatibility apply across the entire FloodStop v4 product family.
| Role | OEM MPN / Spec | Component & Fitment Notes | Est. Street | Check Stock |
|---|---|---|---|---|
| Part 1 oem replacement part |
XS-01 | Extra / Replacement Wired Water Sensor Pad Proprietary 2-prong snap connector requires OEM or compatible part. |
~$39.21 (OEM street) | |
| Part 2 routine consumable |
Single layer of clean dry… | Sensor Dielectric Paper Sleeve Manual explicitly approves a standard paper towel as a substitute. |
<$0.05 | |
| Part 3 oem replacement part |
UL Class 2 9V DC… | 115V AC / 9V DC Class 2 Wall Power Adapter Must be UL Class 2, 9V DC regulated, with matching amperage and barrel polarity to prevent damage or fire. |
~$12–$25 (aftermarket) | |
| Replace Unit | DROP-IN SPEC | Repair Exceeds Appliance Value? Compare verified Smart Washer Flood & Shutoff Valves replacements & cutout specs. |
Compare | See Top Replacements → |
Trigger: Sensor placed on bare metal drain pan, damp concrete, or in high humidity environment.
Physics / Degradation: Missing or saturated paper sleeve, or high ambient conductivity, bridges double-sided sensor traces.
System Lockout / Impact: Nuisance shutoff of water supply and continuous alarm.
Trigger: Aging power supply (notably older black units) or AC power transients.
Physics / Degradation: Unstable DC output voltage or ripple from the adapter.
System Lockout / Impact: System malfunction, alternating LED flashing, or unresettable false alarms.