FloodStop by OnSite FS3: Short beep + LED blink every 45–60 seconds

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

Indicates 4× AA batteries are below 4.2V threshold.

02 // Non-Invasive Meter / Bench Verification

Slide front battery cover to the right and install 4 fresh AA batteries.

Platform / OEM Cross-Reference: Low-battery 4.2V threshold, 45–60 sec blink/beep diagnostics, older black wall-adapter troubleshooting, and extension wire compatibility apply across the entire FloodStop v4 product family.

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
routine consumable
Isolated Match
IEC LR6 (Alkaline) or FR6… Backup Batteries (4× AA)
Standard AA batteries are universally compatible. Lithium AA recommended for longer life and reduced leak risk.
~$4–$10 (4-pack)
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified Smart Washer Flood & Shutoff Valves replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINNOMINAL ON SKU
MOD_02 // POWER & BMSFAULT IMPLICATED
MOD_03 // THERMALNOMINAL ON SKU
MOD_04 // FLUID & WATERNOMINAL ON SKU
MOD_05 // AIRFLOW & ACOUSTICNOMINAL ON SKU
MOD_06 // OPTICAL & SENSORFAULT IMPLICATED
MOD_07 // RF & SMART CTRLNOMINAL ON SKU
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:ABSBRASSEPDMPTFE

Failure Physics & Causal Isolation

Safety & Disassembly Lockouts:
  • Do not use tools on manual override plastic gear.
  • Do not grip plastic motor drive housing for wrench leverage.

Root Failure Mechanism: Backup Battery Depletion / CorrosionClick to spotlight part ↑

01 // Trigger ConditionBatteries drop below 4.2V threshold or are left unreplaced for >1–2 years.
02 // Degradation PhysicsBattery depletion or alkaline leakage corrosion inside the controller battery bay.
03 // Lockout / ImpactPersistent low-battery chirp, potential damage to control unit from corrosion, or loss of backup power during AC outage.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Solid green LED above Open/Close (AC power) OR blinking green LED every 45–60 sec (battery-only).: Solid green indicates AC power is connected. Blinking green every 45–60 seconds (without a beep) is the normal power-saving status indication when running on battery-only mode. (True fault when: If the blinking is accompanied by a short beep every 45-60 seconds, it indicates a low battery warning.)
False-Alarm Check — Brief motor whirring sound once every 30 days.: This is the scheduled 30-day automatic close/open anti-seize cycle, a normal self-maintenance function programmed into the v4 controller to prevent mineral scale buildup. (True fault when: If the motor runs continuously without actuating the valve, or if it occurs more frequently than monthly, it may indicate a fault.)