FA // X-RAYFailureAtlas.orgComponent Triage & OEM MPN Index
HARDWARE SYMPTOM MODEL: IS335 TIER 1–2 BENCH DIY

Honeywell IS335: Continuous Active Trigger in Standby / Inverted State on Access Control REX Input

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

Host access controller (such as Ubiquiti UniFi UA-Hub) interprets the sensor's energized Form A Normally Closed (NC) contact as a continuous active request-to-exit trigger during standby and clears only during the 3-second motion trip window.

02 // Non-Invasive Meter / Bench Verification

Confirm whether the host controller input expects a Normally Closed (NC) intrusion loop or a Normally Open (NO) request-to-exit contact; configure contact polarity inversion in host controller firmware or install an external interposing SPDT relay.

Platform / OEM Cross-Reference: Direct form-fit-function replacement for discontinued Ademco/Honeywell Aurora wired motion detectors

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
accessory
Isolated Match
4-conductor 22 AWG to 20… 4-Conductor Low-Voltage Intrusion Alarm Cable
Matches the 6-position terminal block clamping capacity (22 to 20 AWG) and official Honeywell cable specifications.
~$0.15/ft
Part 2
universal aftermarket part
Isolated Match
Ohmic value dictated by… End-of-Line Resistor (EOLR)
Required by supervised hardwired alarm panel zone inputs; wired in series with NC/C terminals at the sensor.
<$0.25
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified security replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINNOMINAL ON SKU
MOD_02 // POWER & BMSFAULT IMPLICATED
MOD_03 // THERMALNOMINAL ON SKU
MOD_04 // FLUID & WATERNOMINAL ON SKU
MOD_05 // AIRFLOW & ACOUSTICFAULT IMPLICATED
MOD_06 // OPTICAL & SENSORFAULT IMPLICATED
MOD_07 // RF & SMART CTRLFAULT IMPLICATED
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:ABSBRASSCopper

Failure Physics & Causal Isolation

Safety & Disassembly Lockouts:
  • Verify input voltage (>= 9.0 VDC nominal; >= 9.5 VDC for UL 639 Listed installations), power-cycle the detector, and perform a walk test if a supervisory trouble condition (flashing red LED and open relay) occurs; if trouble does not clear, replace the entire sensor.
  • Never connect AC mains or non-power-limited line voltage directly to the 9.0-15.0 VDC Class 2 power-limited input terminals.

Root Failure Mechanism: Form A Normally Closed Contact Logic Inversion on Third-Party Access Control REX InputsClick to spotlight part ↑

01 // Trigger ConditionIntegrating the IS335 as a Request-to-Exit (REX) motion sensor on third-party door access controllers (such as Ubiquiti UniFi UA-Hub) that expect a Normally Open (NO) dry contact closure upon motion.
02 // Degradation PhysicsThe IS335 includes only a single Form A (SPST Normally Closed) relay output (terminals C and NC) with no Normally Open (NO) terminal option; the circuit remains closed during standby and opens for 3 seconds on motion.
03 // Lockout / ImpactDoor access controller remains continuously unlocked/triggered in standby and locks during motion unless controller software supports input polarity inversion or an external interposing relay is added.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Red status LED flashes slowly and the detector does not immediately report normal standby upon applying 12 VDC power.: The IS335 requires up to 45 seconds of initialization warm-up time from initial power application for internal analog amplifiers and dual-slope references to stabilize, during which the red LED flashes slowly by design. (True fault when: If the red LED continues flashing and the Form A alarm relay remains latched open for more than 45 to 60 seconds after power-up with verified supply voltage >= 9.5 VDC.)
False-Alarm Check — Red status LED does not illuminate when a person walks in front of the detector.: The walk-test LED can be intentionally disabled by moving the internal 2-pin LED jumper shunt so the sensor operates discreetly without visible light, while the Form A alarm relay continues to open normally upon motion detection. (True fault when: If the LED jumper shunt is confirmed in the Enabled position, 9.5-15.0 VDC power is present at V+/V-, and neither the LED nor the C/NC relay contact responds during a tangential walk test.)