Symptom Guide Model: IS335

Honeywell IS335: Solid Red LED Illumination and 3.0-Second Relay Opening Without Human Intruder

What this means: Detector registers a valid infrared motion trip and opens the Form A Normally Closed relay contacts for the nominal 3.0-second dwell time due to pets entering upper optical zones, convective HVAC plumes, solar glint, or >3.0 Vpp AC ripple on the DC supply.

1

60-Second Verification Check

⚠ Quick Check Before Buying Parts: Red status LED flashes slowly and the detector does not immediately report normal standby upon applying 12 VDC power. — The IS335 requires up to 45 seconds of initialization warm-up time from initial power application for internal analog amplifiers and dual-slope references to stabilize, during which the red LED flashes slowly by design.

Verify Pet Immunity jumper shunt is in the Enabled position, confirm mounting height is 7 ft 6 in (2.3 m), check that pets cannot climb furniture/stairs within 6 feet of the sensor, and verify at least 4 to 6 feet clearance from HVAC registers and direct window sunlight.

2

Verified Replacement Parts

#1 Most Likely Fix $8.00-$12.00

Swivel Mount Wall Bracket (SMB-10)

SMB-10 Copy Part #

Official Honeywell/Resideo OEM wall swivel bracket listed in IS335 engineering data sheet L/IS335D/D and installation manual IS335-010-V0; note that bracket has not been evaluated by UL for UL 639 certified installations.

Option #2 • Secondary / Related Part $10.00-$14.00

Swivel Mount Ceiling Bracket (SMB-10C)

SMB-10C Copy Part #

Official Honeywell/Resideo OEM ceiling swivel bracket listed in IS335 engineering data sheet L/IS335D/D and installation manual IS335-010-V0; note that bracket has not been evaluated by UL for UL 639 certified installations.

Option #3 • Budget Aftermarket Check Live Stock

Wall / Corner Mounting Screws

B00TYY8LR2 Copy Part #

Fastener size specified in installation manual IS335-010-V0 for securing rear baseplate knockouts to flat walls or 45-degree corners.

Repair Cost Too Close to a New Unit? Compare top-rated drop-in security replacements & dimensions.
Compare Replacements →
Why This Happens & Safety Warnings
Safety & Disassembly Notes:
  • Verify input voltage (>= 9.0 VDC nominal; >= 9.5 VDC for UL 639 Listed installations), power-cycle the detector, and perform a walk test if a supervisory trouble condition (flashing red LED and open relay) occurs; if trouble does not clear, replace the entire sensor.
  • Never connect AC mains or non-power-limited line voltage directly to the 9.0-15.0 VDC Class 2 power-limited input terminals.
Pet Immunity Bypass and False Alarms via Elevated Furniture or Close Proximity (<6 ft)

What triggers it: Domestic pet under the rated 80-lb (36 kg) limit climbs onto a sofa, table, or staircase (>2.5 ft above the floor) or approaches within 6 feet of the wall-mounted detector.

What wears out inside: The 80-lb pet immunity threshold relies on optical spatial masking where floor-dwelling animals only intersect attenuated lower Zone A beams. When an animal elevates into intermediate/long Zone B/C beams or comes within 6 feet of the lens, its subtended infrared thermal footprint equals or exceeds that of an adult human, exceeding the dual-slope comparator trip threshold.

Symptom on machine: False burglar alarm activation while the security system is armed Stay or Away with pets indoors.

Environmental False Alarms from HVAC Air Plumes, Direct Sunlight, or Wall Vibration

What triggers it: Sensor mounted within 4 to 6 feet of forced-air HVAC registers, aimed directly at unshaded windows (>2,000 Lux solar infrared transients), or fastened to a vibrating/unbraced wall surface.

What wears out inside: Rapid thermal air turbulence, solar IR energy exceeding the 2,000 Lux visible-light bug guard, or mechanical oscillation of the optical fan across stationary warm objects induces differential pyroelectric charges indistinguishable from human motion.

Symptom on machine: Recurring false intrusion alarms when HVAC cycles on or sunlight shifts across windows.

Cross-Compatible Platforms: Direct form-fit-function replacement for discontinued Ademco/Honeywell Aurora wired motion detectors

Other Honeywell IS335 Problems (3)