Symptom Guide Model: C21AF002-G0070A12

SANSI C21AF002-G0070A12: Luminaire Stays Continuously Illuminated (Will Not Shut Off)

What this means: Light remains on continuously during daylight or fails to turn off after the motion hold timer expires.

1

60-Second Verification Check

⚠ Quick Check Before Buying Parts: Luminaire illuminates continuously or behaves unresponsively for 1 to 2 minutes immediately after AC breaker power is applied. — The pyroelectric PIR sensor and internal control circuit require a documented 1-to-2-minute thermal stabilization and calibration warm-up cycle upon initial energization before entering normal motion detection.

1. Check the physical slide switch on the sensor pod and RF remote mode to ensure the unit is set to AUTO rather than On-Time or Test mode. 2. Turn the LUX rotary dial toward the Moon icon and reduce RANGE sensitivity to rule out continuous false triggers from HVAC exhaust or foliage. 3. Turn off the circuit breaker for 1-2 minutes to reset the microcontroller and clear any surge-induced latching.

2

Verified Replacement Parts

#1 Most Likely Fix Check Live Stock

Articulated PIR Motion & Photocell Sensor Pod Unit

Articulated PIR Motion… Copy Part #

Hardwired through sealed canopy swivel joint; not available as a modular replacement part.

Repair Cost Too Close to a New Unit? Compare top-rated drop-in outdoor motion sensor security floodlight replacements & dimensions.
Compare Replacements →
Why This Happens & Safety Warnings
Safety & Disassembly Notes:
  • The LED light source is designed for long life and is not user-replaceable. Do not attempt to open the light heads.
  • Do not connect to a dimmer switch. This fixture is not compatible with dimmers.
Continuous Illumination via Control Mode Misconfiguration or Transient Sensor Latching

What triggers it: User leaves slide switch or RF remote in On-Time/D2D mode, sets LUX dial too far toward Sun, or a brief AC utility brownout/transient corrupts the sensor control logic state.

What wears out inside: Control logic either obeys a manual override state stored in non-volatile memory or latches the solid-state switching stage closed until power-cycled.

Symptom on machine: Fixture remains illuminated 24/7 or throughout the night regardless of motion, increasing power consumption (70W continuous) and light trespass.

Nuisance False Motion Activations from Environmental Thermal Plumes or Debris

What triggers it: RANGE dial set to maximum (72 ft) while the 180° sensor cone faces swaying foliage, street traffic, HVAC heat exhaust plumes, or insect webs on the Fresnel lens.

What wears out inside: Moving infrared differentials across the segmented HDPE Fresnel zones trigger the pyroelectric sensor element indistinguishable from human movement.

Symptom on machine: Frequent unwanted night activations and neighborhood glare complaints.

Other SANSI C21AF002-G0070A12 Problems (5)
1. Quick Test 2. See Fix Parts ↓

Type any brand, model number, error code, or part number...