SANSI C21AF002-G0070A12: Rapid On-Off Strobing or Flashing Cycling at Nightfall
What this means: Luminaire turns on when triggered at dusk/night, immediately shuts off within seconds, and repeats a continuous on-off flashing loop.
60-Second Verification Check
1. Verify the branch circuit is NOT connected to an in-wall dimmer switch. 2. Check if the 10,000 lm lamp heads are aimed inward or reflecting off nearby eaves/walls into the sensor pod; re-aim heads outward with at least 1 inch clearance above the sensor. 3. Adjust the LUX dial toward the Moon icon or apply black electrical tape behind the sensor pod to block reflected light.
Verified Replacement Parts
Ceramic SMD 2835 LED Optical Head Sub-Assembly
Permanently integrated non-replaceable assembly; manual explicitly warns not to open light heads.
Internal 70W Potted AC-to-DC Constant-Current LED Driver
Encapsulated in potting compound inside the canopy base; non-replaceable.
Articulated PIR Motion & Photocell Sensor Pod Unit
Hardwired through sealed canopy swivel joint; not available as a modular replacement part.
Why This Happens & Safety Warnings
- The LED light source is designed for long life and is not user-replaceable. Do not attempt to open the light heads.
- Do not connect to a dimmer switch. This fixture is not compatible with dimmers.
What triggers it: Articulating lamp heads are aimed inward, downward near the sensor pod (less than 1 inch clearance), or toward highly reflective nearby eaves, walls, or downspouts.
What wears out inside: Upon motion or dusk activation, the intense 10,000-lumen 5000K beam reflects off adjacent surfaces into the ambient daylight harvesting photodetector, exceeding the LUX cutoff threshold and commanding the control board to shut the light off; once dark, the sensor re-triggers repeatedly.
Symptom on machine: Continuous nuisance on-off strobing/flashing at night, rendering security illumination unusable until heads are re-aimed or the sensor is masked.
What triggers it: Installer connects the 120V AC luminaire input to an existing wall junction box controlled by an in-wall TRIAC, ELV, or rotary dimmer switch.
What wears out inside: Chopped phase-cut AC input waveforms destabilize the internal constant-current switch-mode power converter regulation loop, inducing highdv/dt switching stress, coil overheating, and permanent semiconductor breakdown inside the resin-potted driver cavity.
Symptom on machine: Immediate violent strobing, audible driver buzzing, and permanent non-repairable luminaire failure requiring full fixture replacement.