SANSI C21AF002-G0070A12: Total Luminaire Death (Zero Illumination Output)
What this means: Fixture produces no light output in any mode (Test, On-Time, AUTO, or D2D) despite confirmed 120V AC supply at the junction box.
60-Second Verification Check
Verify 120V AC branch circuit breaker and wall switch are ON, switch sensor pod slide selector to Test mode, and confirm dimmer-Switch absence. If power is present at the junction box and the fixture remains dead in Test mode, the internal potted driver or sealed emitter array has failed and the entire luminaire must be replaced.
Verified Replacement Parts
Ceramic SMD 2835 LED Optical Head Sub-Assembly
Permanently integrated non-replaceable assembly; manual explicitly warns not to open light heads.
Internal 70W Potted AC-to-DC Constant-Current LED Driver
Encapsulated in potting compound inside the canopy base; non-replaceable.
Why This Happens & Safety Warnings
- The LED light source is designed for long life and is not user-replaceable. Do not attempt to open the light heads.
- Do not connect to a dimmer switch. This fixture is not compatible with dimmers.
What triggers it: Installer connects the 120V AC luminaire input to an existing wall junction box controlled by an in-wall TRIAC, ELV, or rotary dimmer switch.
What wears out inside: Chopped phase-cut AC input waveforms destabilize the internal constant-current switch-mode power converter regulation loop, inducing highdv/dt switching stress, coil overheating, and permanent semiconductor breakdown inside the resin-potted driver cavity.
Symptom on machine: Immediate violent strobing, audible driver buzzing, and permanent non-repairable luminaire failure requiring full fixture replacement.
What triggers it: Severe electrical thunderstorm, indirect lightning strike, or utility grid switching transient on the hardwired 120V AC branch circuit.
What wears out inside: High-voltage transient exceeds the breakdown threshold of the internal bridge rectifier or switching MOSFETs inside the encapsulated driver (internal MOV presence/rating is undocumented), and polyurethane/epoxy potting prevents board-level repair.
Symptom on machine: Complete, irreversible luminaire death requiring full unit de-installation and disposal.