FA // X-RAYFailureAtlas.orgComponent Triage & OEM MPN Index
HARDWARE SYMPTOM MODEL: C100 TIER 1–2 BENCH DIY

Wsdcam C100: Red alert LED flashes upon window impact, but the 125 dB acoustic siren emits zero sound

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

Comparator and timer latch circuit are functioning, but the high-output piezoelectric ceramic sounder disc is disconnected, fractured from drop impact, or damped by liquid ingress in the resonant cavity.

02 // Non-Invasive Meter / Bench Verification

Install fresh LR44 batteries first to rule out voltage sag under high-current load; if the LED still flashes brightly on impact with no sound output, replace the sensor puck.

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Isolated Match
C100 Complete Wsdcam C100 / W-8263 Replacement Sensor Puck
Exact base hardware model C100 sold in single-pack, 4-pack (WSD-1541), and 8-pack (WSD-2651 / B08BYKK632) configurations.
$8.99 to $9.99 single pack; $45.99 for 8-pack bundle
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified intrusion detection glass break vibration sensors replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINFAULT IMPLICATED
MOD_02 // POWER & BMSFAULT IMPLICATED
MOD_03 // THERMALNOMINAL ON SKU
MOD_04 // FLUID & WATERNOMINAL ON SKU
MOD_05 // AIRFLOW & ACOUSTICFAULT IMPLICATED
MOD_06 // OPTICAL & SENSORFAULT IMPLICATED
MOD_07 // RF & SMART CTRLNOMINAL ON SKU
MOD_08 // MATERIALS & CHEMINACTIVE
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:ABSBRASS

Failure Physics & Causal Isolation

Safety & Disassembly Lockouts:
  • Do not mix old and new LR44 batteries or mismatched battery chemistries inside the 3-cell series cradle.
  • Mount strictly indoors on clean, dry glass; the enclosure is unsealed (IPX0 equivalent) and must not be exposed to rain or liquid cleaning sprays.

Root Failure Mechanism: Piezoelectric Ceramic Disc Lead-Free Solder Joint Fracture from Drop ImpactClick to spotlight part ↑

01 // Trigger ConditionRepeated mechanical shock impacts when the sensor puck detaches from a tall window pane and strikes a hard floor or windowsill.
02 // Degradation PhysicsHigh-g deceleration shock fractures the brittle solder joints connecting lead wires or PCB pads to the thin silvered electrode layer on the brass-backed PZT ceramic disc.
03 // Lockout / ImpactLoss of 125 dB acoustic output (LED flashes silently on trigger) or complete loss of shock detection.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — The 125 dB siren and flashing red LED automatically shut off and re-arm after approximately 30 seconds of continuous sounding.: The internal analog timer ASIC is deliberately engineered for a ~30-second alarm cycle followed by automatic reset to conserve the three LR44 button cells and comply with residential noise limits. (True fault when: If the siren cuts out after only 1 to 3 seconds or fades rapidly in pitch and volume during an alarm cycle, it indicates severe battery voltage sag or poor terminal contact.)
False-Alarm Check — Tapping or striking an adjacent window pane, an upper double-hung sash, or creating loud airborne glass-shatter noises in the room fails to trip the alarm.: The C100 uses a surface-coupled piezoelectric mechanical shock transducer with no airborne microphone. Mechanical shock waves cannot cross air gaps, vinyl/wood muntins, or separate window sashes; each individual movable glass lite requires its own adhered sensor. (True fault when: If a firm knuckle rap directly on the same continuous glass pane to which the puck is adhered fails to trigger the alarm even at maximum sensitivity with fresh batteries.)

Other Wsdcam C100 Diagnostic Sheets

Type at least 2 characters to search across all 10 HTC hardware divisions...