FA // X-RAYFailureAtlas.orgComponent Triage & OEM MPN Index
HARDWARE SYMPTOM MODEL: C100 TIER 1–2 BENCH DIY

Wsdcam C100: Red indicator LED flashing without alarm or appearing dim / weak siren output

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

Manufacturer-documented low-voltage alert indicating the three series LR44 alkaline cells are nearing depletion.

02 // Non-Invasive Meter / Bench Verification

Slide open the rear battery hatch and replace all three LR44 button cells simultaneously, observing correct polarity (+ facing up).

Platform / OEM Cross-Reference: The C100 hardware is a shared OEM platform manufactured by Shenzhen Youfeiyang Electronics Co., Ltd. / WSDCAM International Limited and distributed under Wsdcam (WSD-1541 4-pack, WSD-2651 8-pack) and white-label brands such as EverNary.

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
routine consumable
Isolated Match
LR44 LR44 1.5V Alkaline Button Cell Batteries (3 per puck / 12 per 4-pack)
Confirmed in OEM manual and retail specifications; replace all 3 cells in a puck simultaneously and do not mix chemistries or old/new cells.
$0.25 to $0.60 per cell in multipacks
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified autonomous surface vibration window alarm replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINNOMINAL ON SKU
MOD_02 // POWER & BMSFAULT IMPLICATED
MOD_03 // THERMALNOMINAL ON SKU
MOD_04 // FLUID & WATERNOMINAL ON SKU
MOD_05 // AIRFLOW & ACOUSTICNOMINAL ON SKU
MOD_06 // OPTICAL & SENSORFAULT IMPLICATED
MOD_07 // RF & SMART CTRLFAULT IMPLICATED
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:ABSLithium-Ion

Failure Physics & Causal Isolation

Safety & Disassembly Lockouts:
  • Strictly for indoor use only; do not expose to rain or immerse in water.
  • Do not mix old and new batteries or different battery chemistries; observe correct polarity (+ facing up) when inserting LR44 cells.

Root Failure Mechanism: Accelerated LR44 Button Cell Depletion Under Repeated Siren ActivationsClick to spotlight part ↑

01 // Trigger ConditionRepeated 30-second alarm activations caused by ambient environmental vibrations or elevated summer window temperatures accelerating cell self-discharge.
02 // Degradation Physics0.28 W active siren load (~62 mA at 4.5V DC) rapidly depletes the limited ~115–150 mAh capacity of the three series LR44 alkaline coin cells within ~80 cumulative minutes of active output.
03 // Lockout / ImpactBatteries exhaust far earlier than the advertised ~12-month standby interval, increasing consumable replacement frequency across the 12 cells in a 4-pack.

Root Failure Mechanism: Silent Loss of Intrusion Protection Following Unnoticed Battery DepletionClick to spotlight part ↑

01 // Trigger ConditionSensor mounted behind window curtains, blinds, or in low-traffic rooms where visual low-battery LED flashes are obscured and periodic tap testing is omitted.
02 // Degradation PhysicsLR44 cells discharge below the comparator and oscillator operating voltage threshold without remote telemetry or persistent audible low-voltage trouble beeps.
03 // Lockout / ImpactUnit silently ceases functioning, leaving the window pane completely unprotected while the owner assumes the perimeter is armed.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — The 125 dB siren stops sounding automatically after 30 seconds even though the ON/OFF switch remains in the ON position.: The analog timer circuit is specifically engineered for a 30-second automatic timeout per trigger event and re-arms automatically once vibration ceases to conserve the miniature LR44 button cells. (True fault when: Indicates a fault only if the siren cuts out within a few seconds with a weak warble or dim LED, signaling depleted LR44 batteries.)
False-Alarm Check — Striking or breaking an adjacent window sash, secondary mullioned lite, or nearby glass object does not trigger the sensor.: The C100 uses a surface-coupled piezoelectric vibration sensor with no microphone; mechanical stress waves are damped across window frame mullions and sashes, so each puck monitors only the single sheet of glass to which it is adhered. (True fault when: Indicates a fault only if the sensor fails to trip when tapping directly on the specific glass pane to which it is mounted at high sensitivity.)

Other Wsdcam C100 Diagnostic Sheets