Wsdcam C100: Unit fails to sound alarm or flash LED when window glass is tapped while armed
What this means: Observed when LR44 cells are completely exhausted, battery contacts are corroded by leaked KOH electrolyte, the sensitivity roller is set too low, or the PSA pad has partially delaminated and damped shock transmission.
60-Second Verification Check
Confirm slide switch is in the ON position, increase sensitivity via the side thumbwheel, inspect the battery compartment for dead cells or white crystalline KOH residue, and verify the foam pad is tightly bonded to the pane.
Verified Replacement Parts
LR44 1.5V Alkaline Button Cell Batteries (3 per puck / 12 per 4-pack)
Confirmed in OEM manual and retail specifications; replace all 3 cells in a puck simultaneously and do not mix chemistries or old/new cells.
Pre-Cut Circular Double-Sided Acrylic Foam PSA Mounting Pad
Must provide sufficient viscoelastic shear stiffness to support a 34 g vertical load under solar glass heating while coupling mechanical vibration from the pane to the ABS housing base.
Why This Happens & Safety Warnings
- Strictly for indoor use only; do not expose to rain or immerse in water.
- Do not mix old and new batteries or different battery chemistries; observe correct polarity (+ facing up) when inserting LR44 cells.
What triggers it: Sensor mounted behind window curtains, blinds, or in low-traffic rooms where visual low-battery LED flashes are obscured and periodic tap testing is omitted.
What wears out inside: LR44 cells discharge below the comparator and oscillator operating voltage threshold without remote telemetry or persistent audible low-voltage trouble beeps.
Symptom on machine: Unit silently ceases functioning, leaving the window pane completely unprotected while the owner assumes the perimeter is armed.
What triggers it: Depleted LR44 alkaline cells left inside the battery compartment over prolonged periods or subjected to high solar heat load on sun-facing windows.
What wears out inside: Internal gas generation and thermal expansion rupture the miniature button cell crimp seal, releasing aqueous potassium hydroxide (KOH) electrolyte that corrodes the nickel-plated spring contacts.
Symptom on machine: High contact resistance or open circuit prevents power delivery to the PCB, rendering the non-serviceable sensor puck permanently non-functional.
Cross-Compatible Platforms: The C100 hardware is a shared OEM platform manufactured by Shenzhen Youfeiyang Electronics Co., Ltd. / WSDCAM International Limited and distributed under Wsdcam (WSD-1541 4-pack, WSD-2651 8-pack) and white-label brands such as EverNary.