Whirlpool WRS325SDHZ: Continuous water puddling on dispenser drip tray or floor with visible frost inside the ice chute throat
⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK
01 // Observed Condition
Ambient humid air enters past a warped, fatigued, or ice-propped chute door seal, freezes inside the chute, and melts down the front door.
02 // Non-Invasive Meter / Bench Verification
Visually inspect inside the dispenser chute with a flashlight for ice shavings holding the flapper open or a gap around seal W11678832; dispense 8 to 10 whole cubes after crushed ice use to clear shavings.
Platform / OEM Cross-Reference: Adaptive Defrost Control (ADC) runtime bounds (8 to 96 hours of compressor runtime) and UI diagnostic test sequences (Service Tests 1, 2, 37, 38) derive from shared Whirlpool platform tech sheets.