Whirlpool WRS325SDHZ: Ice maker harvest fingers/tray cycle dry with no ice output while door water dispenser flows normally
What this means: Ice maker mechanical harvest runs, but water fails to enter the freezer mold due to a frozen fill tube, unseated filter bypass, or failed ice-side solenoid on the dual inlet valve.
60-Second Verification Check
Verify EDR1RXD1 filter is fully seated and less than 6 months old, check that household water pressure is 30 to 120 psi, and inspect upper freezer fill spout for an ice plug; qualified technician tests WPW10179146 solenoid coil (~192 ohms).
Verified Replacement Parts
EveryDrop Filter 1 Water Filter Cartridge
Exact OEM consumable specified for WRS325SDHZ; third-party equivalents must match locking lug and bypass-pin actuation geometry.
Dual-Solenoid Water Inlet Valve
Confirmed SKU-specific dual-coil solenoid valve (~192 ohms coil resistance; rated 30 to 120 psi).
Water Filter Head and Bypass Housing
Confirmed SKU-specific filter manifold with internal bypass poppet for EDR1RXD1.
Why This Happens & Safety Warnings
- Contains ASHRAE Class A3 highly flammable R-600a (isobutane) refrigerant (150 g EPA SNAP cap); open-flame torch brazing is prohibited and sealed-system work requires dry nitrogen purging, combustible gas monitoring, sparkless vacuum pumps, and Lokring mechanical fittings.
- Do not use sharp metallic instruments to scrape frost or clean coils due to puncture and flammable refrigerant release risk.
What triggers it: Household water line pressure below 30 psi, restrictive saddle-valve tap, overdue clogged EDR1RXD1 filter, or mineral-scaled valve seat.
What wears out inside: Dual-solenoid inlet valve WPW10179146 fails to retract or seal cleanly, sending a low-velocity trickle or weep into the sub-zero freezer delivery tube where water freezes progressively into a solid plug.
Symptom on machine: Complete cessation of ice production while door chilled-water dispensing often continues to operate.
What triggers it: Incomplete insertion of replacement cartridge EDR1RXD1, incompatible third-party cartridge geometry, or internal wear of housing W11162042.
What wears out inside: Filter fails to depress the internal bypass poppet inside housing W11162042, leaving the upstream hydraulic path shut off.
Symptom on machine: Zero water flow to both the exterior water dispenser and the interior ice maker.
Cross-Compatible Platforms: Adaptive Defrost Control (ADC) runtime bounds (8 to 96 hours of compressor runtime) and UI diagnostic test sequences (Service Tests 1, 2, 37, 38) derive from shared Whirlpool platform tech sheets.