Whirlpool WRS325SDHZ: Repetitive metallic click every 2 to 5 minutes with rising compartment temperatures or compressor humming
What this means: Compressor attempts to start, fails to engage run RPM, and trips overload protection every 2 to 5 minutes while both freezer and refrigerator warm up.
60-Second Verification Check
Confirm unit is plugged directly into a dedicated 115V outlet without extension cords and rear clearances are unobstructed; qualified technician disconnects power to inspect PTC relay WPW10197428 for loose rattling ceramic fragments and checks 3 to 6 ohms cold resistance and 12uF run capacitor capacitance.
Verified Replacement Parts
Compressor PTC Starter Relay
Matches OEM cold resistance (3 to 6 ohms) and terminal pin configuration; ensure enclosure rating is approved for R-600a machine compartments.
Compressor Motor Run Capacitor
Exact capacitance (12uF) and minimum AC voltage rating (180V-250V AC) required for compressor run winding phase stability.
Why This Happens & Safety Warnings
- Contains ASHRAE Class A3 highly flammable R-600a (isobutane) refrigerant (150 g EPA SNAP cap); open-flame torch brazing is prohibited and sealed-system work requires dry nitrogen purging, combustible gas monitoring, sparkless vacuum pumps, and Lokring mechanical fittings.
- Do not use sharp metallic instruments to scrape frost or clean coils due to puncture and flammable refrigerant release risk.
What triggers it: Cumulative multi-year compressor start cycles, AC voltage sags/brownouts, extension-cord voltage drop, or high head pressures from poor condenser cooling.
What wears out inside: Semiconducting ceramic pill inside PTC relay WPW10197428 fractures or drifts out of its 3 to 6 ohm cold resistance window (or 12uF capacitor WPW10350564 suffers dielectric loss), failing to energize the compressor start winding.
Symptom on machine: Total loss of refrigeration and freezing across both compartments, risking full food spoilage until external start components are replaced.
Cross-Compatible Platforms: Adaptive Defrost Control (ADC) runtime bounds (8 to 96 hours of compressor runtime) and UI diagnostic test sequences (Service Tests 1, 2, 37, 38) derive from shared Whirlpool platform tech sheets.