Whirlpool WRS325SDHZ: UI Service Test Codes 01 (Pass), 02 (Open), 03 (Short) on Service Tests 1, 2, and 37

⚡ Bench Triage & Meter Telemetry
77°F36°F0°F

01 // Observed Condition

Onboard UI diagnostic mode triggered via control panel button chord (such as SW1 + SW2 for 3 seconds) evaluating FC thermistor (Test 1), RC thermistor (Test 2), and Ice Box thermistor (Test 37): 01 = Pass, 02 = Open circuit, 03 = Short circuit.

02 // Non-Invasive Meter / Bench Verification

Enter UI diagnostic mode from the exterior dispenser panel to read 01/02/03 status codes without cabinet disassembly; qualified technicians verify probe resistance against the 10k Type-2 NTC curve (2.7k ohms at 77°F, 7.9k ohms at 36°F, 23.3k ohms at 0°F).

Platform / OEM Cross-Reference: Adaptive Defrost Control (ADC) runtime bounds (8 to 96 hours of compressor runtime) and UI diagnostic test sequences (Service Tests 1, 2, 37, 38) derive from shared Whirlpool platform tech sheets.

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Isolated Match
W10316760 10k Type-2 NTC Temperature Thermistor Probe
Must strictly follow the 2.7k-ohm-at-25°C B-value curve; standard 10k-at-25°C thermistors are incompatible and will corrupt ADC and damper control.
$20-$30 OEM / $5-$10 compatible aftermarket
Part 2
oem replacement part
Isolated Match
W11449482 Main Electronic Control Board (UI/Jazz Variant)
Proprietary Whirlpool PCB assembly; verify two-digit SKU revision suffix when ordering.
$180-$210 OEM
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified side by side refrigerator replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINNOMINAL ON SKU
MOD_02 // POWER & BMSNOMINAL ON SKU
MOD_03 // THERMALFAULT IMPLICATED
MOD_04 // FLUID & WATERNOMINAL ON SKU
MOD_05 // AIRFLOW & ACOUSTICNOMINAL ON SKU
MOD_06 // OPTICAL & SENSORFAULT IMPLICATED
MOD_07 // RF & SMART CTRLFAULT IMPLICATED
MOD_08 // MATERIALS & CHEMNOMINAL ON SKU
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:ABSActivated CarbonCopperEepromNTCPTCSiliconeStainless Steel

Failure Physics & Causal Isolation

Safety & Disassembly Lockouts:
  • Contains ASHRAE Class A3 highly flammable R-600a (isobutane) refrigerant (150 g EPA SNAP cap); open-flame torch brazing is prohibited and sealed-system work requires dry nitrogen purging, combustible gas monitoring, sparkless vacuum pumps, and Lokring mechanical fittings.
  • Do not use sharp metallic instruments to scrape frost or clean coils due to puncture and flammable refrigerant release risk.

Root Failure Mechanism: 10k Type-2 NTC Thermistor Open/Short Fault or Mismatched Aftermarket SubstitutionClick to spotlight part ↑

01 // Trigger ConditionSensor moisture ingress/aging or installation of a generic 10k-at-25°C thermistor instead of the required 2.7k-at-25°C Type-2 B-value curve.
02 // Degradation PhysicsOpen/short sensor failure or skewed analog resistance-to-temperature feedback corrupts main board W11449482 damper positioning and Adaptive Defrost Control runtime calculations.
03 // Lockout / ImpactOvercooling/freezing of fresh food, warm compartment temperatures, or mistimed defrost intervals.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — A distinct single audible click from the lower rear cabinet as the compressor starts or stops: Normal electromechanical/PTC starter relay disengagement physics as the start winding drops out once the compressor reaches running speed. (True fault when: Indicates a fault only when clicking repeats cyclically every 2 to 5 minutes accompanied by compressor humming, failure to run, and rising interior temperatures.)
False-Alarm Check — Two to three drops of water falling from the dispenser spigot immediately after releasing the paddle: Normal hydraulic line pressure relief in the downstream dispenser tubing after solenoid valve closure. (True fault when: Indicates a fault when dripping continues steadily, forms continuous puddles on the drip tray or floor, or coincides with visible frost buildup inside the ice chute.)