Whirlpool WRS325SDHZ: UI Service Test Codes 01 (Pass), 02 (Open), 03 (Short) on Service Tests 1, 2, and 37
⚡ Bench Triage & Meter Telemetry
77°F36°F0°F
01 // Observed Condition
Onboard UI diagnostic mode triggered via control panel button chord (such as SW1 + SW2 for 3 seconds) evaluating FC thermistor (Test 1), RC thermistor (Test 2), and Ice Box thermistor (Test 37): 01 = Pass, 02 = Open circuit, 03 = Short circuit.
02 // Non-Invasive Meter / Bench Verification
Enter UI diagnostic mode from the exterior dispenser panel to read 01/02/03 status codes without cabinet disassembly; qualified technicians verify probe resistance against the 10k Type-2 NTC curve (2.7k ohms at 77°F, 7.9k ohms at 36°F, 23.3k ohms at 0°F).
Platform / OEM Cross-Reference: Adaptive Defrost Control (ADC) runtime bounds (8 to 96 hours of compressor runtime) and UI diagnostic test sequences (Service Tests 1, 2, 37, 38) derive from shared Whirlpool platform tech sheets.