Symptom Guide Model: WRS325SDHZ

Whirlpool WRS325SDHZ: Heavy frost buildup on inner rear freezer wall accompanied by warm fresh-food compartment (or freezing fresh food if damper sticks open)

What this means: Evaporator frost blanket blocks forced airflow from the single freezer evaporator, or partition air damper louver fails to modulate cold air spill into the refrigerator compartment.

1

60-Second Verification Check

⚠ Quick Check Before Buying Parts: A distinct single audible click from the lower rear cabinet as the compressor starts or stops — Normal electromechanical/PTC starter relay disengagement physics as the start winding drops out once the compressor reaches running speed.

Check perimeter door gaskets for air gaps and run onboard UI Service Test #38 (Forced Defrost) or damper actuation test; qualified technician checks heater WP2323198 continuity (28 to 33 ohms normal; above 300 ohms indicates open failure).

Target: 28 to 33 ohmsTarget: 300 ohms
2

Verified Replacement Parts

#1 Most Likely Fix $50-$75 OEM / $30-$40 aftermarket

Radiant Evaporator Defrost Heater

WP2323198 Copy Part #

Confirmed SKU-specific heater element; healthy bench resistance is 28 to 33 ohms.

Option #2 • Secondary / Related Part $80-$125 OEM / $40-$50 aftermarket

Partition Air Damper Control Assembly

W11164593 Copy Part #

Confirmed SKU-specific partition diffuser assembly.

Option #3 • Secondary / Related Part $180-$210 OEM

Main Electronic Control Board (UI/Jazz Variant)

W11449482 Copy Part #

Proprietary Whirlpool PCB assembly; verify two-digit SKU revision suffix when ordering.

Repair Cost Too Close to a New Unit? Compare top-rated drop-in side by side refrigerator replacements & dimensions.
Compare Replacements →
Why This Happens & Safety Warnings
Safety & Disassembly Notes:
  • Contains ASHRAE Class A3 highly flammable R-600a (isobutane) refrigerant (150 g EPA SNAP cap); open-flame torch brazing is prohibited and sealed-system work requires dry nitrogen purging, combustible gas monitoring, sparkless vacuum pumps, and Lokring mechanical fittings.
  • Do not use sharp metallic instruments to scrape frost or clean coils due to puncture and flammable refrigerant release risk.
Evaporator Defrost Heater Burnout or Bimetal Fault Causing Frost Encapsulation and Warm RC

What triggers it: Repeated ADC active defrost heating cycles over long-term operation or moisture load from door openings/gasket leaks.

What wears out inside: Calrod/glass-tube defrost heater WP2323198 burns open (resistance rising from normal 28 to 33 ohms to above 300 ohms/infinite) or series bimetal thermostat fails open, preventing frost melt when commanded by main board W11449482.

Symptom on machine: Solid frost blankets the single freezer evaporator coil, choking airflow across the fins and starving the fresh-food compartment of cooling.

Motorized Partition Air Damper Mechanical Jam or Synchronous Motor Failure

What triggers it: Frost accumulation on the mullion louver or wear of the 120V synchronous/stepper motor gear train in W11164593.

What wears out inside: Damper louver stalls in either the open or closed position, decoupling fresh-food cooling from thermistor setpoint control.

Symptom on machine: If stuck open, sub-zero freezer air freezes produce and liquids in the RC; if stuck closed, RC warms up while FC remains near 0°F.

Cross-Compatible Platforms: Adaptive Defrost Control (ADC) runtime bounds (8 to 96 hours of compressor runtime) and UI diagnostic test sequences (Service Tests 1, 2, 37, 38) derive from shared Whirlpool platform tech sheets.

Other Whirlpool WRS325SDHZ Problems (5)
1. Quick Test 2. See Fix Parts ↓