FA // X-RAYFailureAtlas.orgComponent Triage & OEM MPN Index
EQUIPMENT DOWN? Interactive Bench Isolation & Verified OEM Fix Kit Below
Jump to Fix Kit ↓
EXPLICIT FAULT CODE MODEL: WKEX200HBA TIER 1–2 BENCH DIY

LG WKEX200HBA: d75, d80, d85, d90, d95 (FlowSense Exhaust Restriction Codes)

⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK

01 // Observed Condition

Dryer detects 75% to 95% airflow restriction in the exhaust duct loop; dryer halts operation at d90/d95 to prevent overheating and lint ignition.

02 // Non-Invasive Meter / Bench Verification

Clean lint filter ADQ56656403 with warm soapy water. Disconnect the 4 in. building exhaust duct from the rear of the WashTower and run the 3-minute InS Installation Duct Check test. If InS passes with the house vent disconnected, the WashTower hardware is healthy and the house ductwork/exterior hood is blocked. If d80-d95 persists with the rear vent disconnected, inspect internal transition duct AEC73857503, blower wheel, NTC thermistor AGM30045804, and high-limit thermostat 6931EL3003D (opens at 257F +/- 9F).

Platform / OEM Cross-Reference: 200-Series Electric Color Variants (WKEX200HWA White, WKEX200HGA Nature Green, WKEX200HRA Candy Apple Red) are identical in internal hardware to WKEX200HBA.

Verified Replacement Parts & OEM Fix KitSelect an assembly or test result to spotlight matching MPN

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
routine consumable
Isolated Match
ADQ56656403 Dryer Kidney-Style Nylon Mesh Lint Filter Screen
Exact OEM part number verified on WKEX200HBA parts diagrams.
OEM: $52.95-$62.62 / Generic Aftermarket: $14-$22
Part 2
oem replacement part
Isolated Match
6931EL3003D Dryer High-Limit Thermal Cutoff (257F), Cycling Thermostat & 10 kOhm NTC Thermistor
Confirmed OEM part numbers and supersessions (6323EL2001B -> AGM30045804) on WKEX200HBA parts diagrams.
OEM 6931EL3003D: $18.24-$19.53; OEM AGM30045804: $93.95-$113.72 / Generic Kit (Fuse + NTC): $12-$20
Part 3
oem replacement part
Isolated Match
Pos F110 Dryer 240V 5,400W Dual-Coil Electric Heating Element Tunnel Assembly
Exact OEM part number at Pos F110 on WKEX200HBA exploded diagrams.
OEM Full Assembly: $218.95-$247.05 / Generic Coil/Tunnel: $35-$55
Replace Unit
drop-in spec
SYSTEM SPEC Repair Exceeds Hardware Value?
Compare verified stacked washer dryer laundry center replacements & dimensional specs.
Compare See Top Replacements →

8-Bus Subsystem X-Ray & Implicated AssembliesROLE 1 + ROLE 2 HARDWARE GRAPH

MOD_01 // CHASSIS & DRIVETRAINFAULT IMPLICATED
MOD_02 // POWER & BMSNOMINAL ON SKU
MOD_03 // THERMALFAULT IMPLICATED
MOD_04 // FLUID & WATERFAULT IMPLICATED
MOD_05 // AIRFLOW & ACOUSTICFAULT IMPLICATED
MOD_06 // OPTICAL & SENSORFAULT IMPLICATED
MOD_07 // RF & SMART CTRLNOMINAL ON SKU
MOD_08 // MATERIALS & CHEMFAULT IMPLICATED
Tap Assembly to Spotlight Part:
Material / Sensor Nodes:ABSBLDCCarbon SteelCarbon-SteelCast AluminumCast-AluminumCopperEPDM

Failure Physics & Causal Isolation

Safety & Disassembly Lockouts:
  • SHOCK HAZARD: Internal components (pump, valves, motors, control boards) are intentionally not grounded to the sheet-metal chassis and may be electrically live when energized; always disconnect both the 120V washer power cord and the 240V/208V dryer circuit before servicing.
  • TIP & CRUSH HAZARD: Never lay the 311 lb stacked WashTower on its back or side during service, and never mount the unit on a laundry pedestal.

Root Failure Mechanism: Dryer Exhaust Restriction, Overheating & High-Limit Thermal Cutoff Trip (d75/d80/d85/d90/d95)Click to spotlight part ↑

01 // Trigger ConditionLint accumulation inside the internal transition duct (AEC73857503) or external building 4 in. vent, crushed rear duct (<4 in. rear clearance), or hydrophobic dryer-sheet wax film coating nylon lint screen ADQ56656403.
02 // Degradation PhysicsRestricted convective airflow traps 5,400W heat inside the heater tunnel (5301EL1001H), elevating heater box temperature to 257F +/- 9F (125C +/- 5C), which triggers FlowSense d75-d95 warnings and blows high-limit thermal cutoff 6931EL3003D (or blower thermostat 6931EL3002M).
03 // Lockout / ImpactDryer shuts down with d90/d95 error code or tumbles completely cold (no heat); service visits caused by restricted house exhaust ductwork are excluded from factory warranty coverage.

Before Ordering Parts: Normal Operation vs. True Fault

False-Alarm Check — Water level inside the lower front-load washer drum does not visibly rise above the bottom rim of the tempered door glass during wash cycles.: As an ENERGY STAR CEE Tier 2 High-Efficiency horizontal-axis washer (IWF 2.9 gal/cu. ft.), garments are saturated via gravity drop-and-tumble action through a concentrated sump pool combined with pressurized TurboWash 360 recirculation spray jets rather than deep-water immersion. (True fault when: Indicates a fault only if the washer posts an IE (Inlet Error) code or garments emerge completely dry after a cycle.)
False-Alarm Check — After pressing Start, the lower washer locks the door and tumbles dry laundry back and forth for several seconds before opening the water inlet valves.: This is the normal AI DD (Artificial Intelligence Direct Drive) load-sensing phase, which measures dry textile mass and fabric softness via 3-phase BLDC motor torque and Hall-sensor feedback to calculate optimal water volume and drum motion profiles. (True fault when: Indicates a fault only if the drum fails to turn (posting LE) or fails to admit water after load sensing completes (posting IE).)

Other LG WKEX200HBA Diagnostic Sheets

Type at least 2 characters to search across all 10 HTC hardware divisions...