LG WKEX200HBA: d75, d80, d85, d90, d95 (FlowSense Exhaust Restriction Codes)
⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK
01 // Observed Condition
Dryer detects 75% to 95% airflow restriction in the exhaust duct loop; dryer halts operation at d90/d95 to prevent overheating and lint ignition.
02 // Non-Invasive Meter / Bench Verification
Clean lint filter ADQ56656403 with warm soapy water. Disconnect the 4 in. building exhaust duct from the rear of the WashTower and run the 3-minute InS Installation Duct Check test. If InS passes with the house vent disconnected, the WashTower hardware is healthy and the house ductwork/exterior hood is blocked. If d80-d95 persists with the rear vent disconnected, inspect internal transition duct AEC73857503, blower wheel, NTC thermistor AGM30045804, and high-limit thermostat 6931EL3003D (opens at 257F +/- 9F).
Platform / OEM Cross-Reference: 200-Series Electric Color Variants (WKEX200HWA White, WKEX200HGA Nature Green, WKEX200HRA Candy Apple Red) are identical in internal hardware to WKEX200HBA.