LG WKEX200HBA: UE / uE (Unbalanced Load Error) & Violent 1,300 RPM Spin Vibration
⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK
01 // Observed Condition
Washer detects excessive drum excursion during spin extraction and either pauses to rebalance (lowercase uE) or halts with an unbalance fault (uppercase UE).
02 // Non-Invasive Meter / Bench Verification
On newly delivered units, push the inner wash drum by hand—if rigid, the 4 rear shipping bolts (FAA31690703-05) were left installed. Next, run a Rinse+Spin cycle with an empty drum. Lowercase uE or isolated UE on a single heavy item (bathmat/duvet) is normal load physics; persistent UE or violent shaking with an empty or balanced load indicates worn telescopic friction shocks (ACV72909506), unlevel feet (AFC72755401), flexible subflooring, or a corroded spider arm (MHW62501207).
Platform / OEM Cross-Reference: 200-Series Electric Color Variants (WKEX200HWA White, WKEX200HGA Nature Green, WKEX200HRA Candy Apple Red) are identical in internal hardware to WKEX200HBA.