Observed Condition: Dryer detects an open or shorted NTC thermistor circuit (tE1/tE2), or the drum tumbles normally with zero thermal output.
Immediate Non-Invasive Triage: First verify at the household electrical panel that both legs of the double-pole 240V/30A breaker are untripped (a tripped L2 leg allows the 120V motor to tumble the drum with no 240V heat). If 240V AC is present at the terminal block, a technician tests continuity across high-limit thermal cutoff 6931EL3003D and heating element 5301EL1001H, and checks NTC thermistor AGM30045804 (~10 kOhms at 25C).
Platform Cross-Reference: 200-Series Electric Color Variants (WKEX200HWA White, WKEX200HGA Nature Green, WKEX200HRA Candy Apple Red) are identical in internal hardware to WKEX200HBA.
| Role | OEM MPN / Spec | Component & Fitment Notes | Est. Street | Check Stock |
|---|---|---|---|---|
| Part 1 oem replacement part |
Pos F110 | Dryer 240V 5,400W Dual-Coil Electric Heating Element Tunnel Assembly Exact OEM part number at Pos F110 on WKEX200HBA exploded diagrams. |
OEM Full Assembly: $218.95-$247.05 / Generic Coil/Tunnel: $35-$55 | |
| Part 2 oem replacement part |
6931EL3003D | Dryer High-Limit Thermal Cutoff (257F), Cycling Thermostat & 10 kOhm NTC Thermistor Confirmed OEM part numbers and supersessions (6323EL2001B -> AGM30045804) on WKEX200HBA parts diagrams. |
OEM 6931EL3003D: $18.24-$19.53; OEM AGM30045804: $93.95-$113.72 / Generic Kit (Fuse + NTC): $12-$20 | |
| Part 3 routine consumable |
ADQ56656403 | Dryer Kidney-Style Nylon Mesh Lint Filter Screen Exact OEM part number verified on WKEX200HBA parts diagrams. |
OEM: $52.95-$62.62 / Generic Aftermarket: $14-$22 | |
| Replace Unit | DROP-IN SPEC | Repair Exceeds Appliance Value? Compare verified stacked washer dryer laundry center replacements & cutout specs. |
Compare | See Top Replacements → |
Trigger: Lint accumulation inside the internal transition duct (AEC73857503) or external building 4 in. vent, crushed rear duct (<4 in. rear clearance), or hydrophobic dryer-sheet wax film coating nylon lint screen ADQ56656403.
Physics / Degradation: Restricted convective airflow traps 5,400W heat inside the heater tunnel (5301EL1001H), elevating heater box temperature to 257F +/- 9F (125C +/- 5C), which triggers FlowSense d75-d95 warnings and blows high-limit thermal cutoff 6931EL3003D (or blower thermostat 6931EL3002M).
System Lockout / Impact: Dryer shuts down with d90/d95 error code or tumbles completely cold (no heat); service visits caused by restricted house exhaust ductwork are excluded from factory warranty coverage.
Trigger: Repeated high-temperature thermal cycling and lint blanketing across the blower housing and 5,400W heater tunnel.
Physics / Degradation: NTC thermistor AGM30045804 (supersedes 6323EL2001B) drifts away from its nominal ~10 kOhm (@ 25C) curve or shorts/opens, or the dual nichrome coils inside heating element 5301EL1001H suffer brittle oxidation fracture.
System Lockout / Impact: Dryer halts with tE1/tE2 error code or tumbles full cycles without generating heat.