UNIT DOWN? Verified OEM & Aftermarket Fix Kit Below
Jump to Parts Kit ↓
HARDWARE SYMPTOM MODEL: WKEX200HBA

LG WKEX200HBA: tE1, tE2 (Dryer Temperature Sensor Fault) or Dryer Tumbles Without Heat

Observed Condition: Dryer detects an open or shorted NTC thermistor circuit (tE1/tE2), or the drum tumbles normally with zero thermal output.

Immediate Non-Invasive Triage: First verify at the household electrical panel that both legs of the double-pole 240V/30A breaker are untripped (a tripped L2 leg allows the 120V motor to tumble the drum with no 240V heat). If 240V AC is present at the terminal block, a technician tests continuity across high-limit thermal cutoff 6931EL3003D and heating element 5301EL1001H, and checks NTC thermistor AGM30045804 (~10 kOhms at 25C).

Platform Cross-Reference: 200-Series Electric Color Variants (WKEX200HWA White, WKEX200HGA Nature Green, WKEX200HRA Candy Apple Red) are identical in internal hardware to WKEX200HBA.

Verified Replacement Parts & Fix Kit

RoleOEM MPN / SpecComponent & Fitment NotesEst. StreetCheck Stock
Part 1
oem replacement part
Pos F110 Dryer 240V 5,400W Dual-Coil Electric Heating Element Tunnel Assembly
Exact OEM part number at Pos F110 on WKEX200HBA exploded diagrams.
OEM Full Assembly: $218.95-$247.05 / Generic Coil/Tunnel: $35-$55
Part 2
oem replacement part
6931EL3003D Dryer High-Limit Thermal Cutoff (257F), Cycling Thermostat & 10 kOhm NTC Thermistor
Confirmed OEM part numbers and supersessions (6323EL2001B -> AGM30045804) on WKEX200HBA parts diagrams.
OEM 6931EL3003D: $18.24-$19.53; OEM AGM30045804: $93.95-$113.72 / Generic Kit (Fuse + NTC): $12-$20
Part 3
routine consumable
ADQ56656403 Dryer Kidney-Style Nylon Mesh Lint Filter Screen
Exact OEM part number verified on WKEX200HBA parts diagrams.
OEM: $52.95-$62.62 / Generic Aftermarket: $14-$22
Replace Unit DROP-IN SPEC Repair Exceeds Appliance Value?
Compare verified stacked washer dryer laundry center replacements & cutout specs.
Compare See Top Replacements →

Failure Physics & Technician Isolation

Safety & Disassembly Warnings:
  • SHOCK HAZARD: Internal components (pump, valves, motors, control boards) are intentionally not grounded to the sheet-metal chassis and may be electrically live when energized; always disconnect both the 120V washer power cord and the 240V/208V dryer circuit before servicing.
  • TIP & CRUSH HAZARD: Never lay the 311 lb stacked WashTower on its back or side during service, and never mount the unit on a laundry pedestal.

Root Mechanism: Dryer Exhaust Restriction, Overheating & High-Limit Thermal Cutoff Trip (d75/d80/d85/d90/d95)

Trigger: Lint accumulation inside the internal transition duct (AEC73857503) or external building 4 in. vent, crushed rear duct (<4 in. rear clearance), or hydrophobic dryer-sheet wax film coating nylon lint screen ADQ56656403.

Physics / Degradation: Restricted convective airflow traps 5,400W heat inside the heater tunnel (5301EL1001H), elevating heater box temperature to 257F +/- 9F (125C +/- 5C), which triggers FlowSense d75-d95 warnings and blows high-limit thermal cutoff 6931EL3003D (or blower thermostat 6931EL3002M).

System Lockout / Impact: Dryer shuts down with d90/d95 error code or tumbles completely cold (no heat); service visits caused by restricted house exhaust ductwork are excluded from factory warranty coverage.

Root Mechanism: Dryer NTC Thermistor Resistance Drift (tE1/tE2) or 5,400W Heating Element Open Circuit

Trigger: Repeated high-temperature thermal cycling and lint blanketing across the blower housing and 5,400W heater tunnel.

Physics / Degradation: NTC thermistor AGM30045804 (supersedes 6323EL2001B) drifts away from its nominal ~10 kOhm (@ 25C) curve or shorts/opens, or the dual nichrome coils inside heating element 5301EL1001H suffer brittle oxidation fracture.

System Lockout / Impact: Dryer halts with tE1/tE2 error code or tumbles full cycles without generating heat.

Before Ordering Parts: Normal Behavior vs. True Fault

False-Alarm Check — Water level inside the lower front-load washer drum does not visibly rise above the bottom rim of the tempered door glass during wash cycles.: As an ENERGY STAR CEE Tier 2 High-Efficiency horizontal-axis washer (IWF 2.9 gal/cu. ft.), garments are saturated via gravity drop-and-tumble action through a concentrated sump pool combined with pressurized TurboWash 360 recirculation spray jets rather than deep-water immersion. (True fault when: Indicates a fault only if the washer posts an IE (Inlet Error) code or garments emerge completely dry after a cycle.)
False-Alarm Check — After pressing Start, the lower washer locks the door and tumbles dry laundry back and forth for several seconds before opening the water inlet valves.: This is the normal AI DD (Artificial Intelligence Direct Drive) load-sensing phase, which measures dry textile mass and fabric softness via 3-phase BLDC motor torque and Hall-sensor feedback to calculate optimal water volume and drum motion profiles. (True fault when: Indicates a fault only if the drum fails to turn (posting LE) or fails to admit water after load sensing completes (posting IE).)

Other LG WKEX200HBA Fault Signals