Error Code Model: WKEX200HBA

LG WKEX200HBA: dE, dE1, dE2, dE4 (Washer / Dryer Door Interlock Faults)

What this means: Control board does not detect a closed and locked door state; cycle refuses to start and door lock may click repeatedly.

1

60-Second Verification Check

⚠ Quick Check Before Buying Parts: Water level inside the lower front-load washer drum does not visibly rise above the bottom rim of the tempered door glass during wash cycles. — As an ENERGY STAR CEE Tier 2 High-Efficiency horizontal-axis washer (IWF 2.9 gal/cu. ft.), garments are saturated via gravity drop-and-tumble action through a concentrated sump pool combined with pressurized TurboWash 360 recirculation spray jets rather than deep-water immersion.

Inspect the EPDM door boot (MDS66290824) for trapped laundry obstructing the door and press the door firmly at the 3 o'clock latch position. If the error persists with an unobstructed doorway and aligned hinge (MEF64762201), test continuity across the washer PTC/solenoid lock switch (EBF61315802) or dryer door switch (4027EL1001A / EBF61496102).

2

Verified Replacement Parts

#1 Most Likely Fix OEM Boot: $93.95-$165.95; Clamp: $18.16-$19.95 / Generic Boot: $45-$65

Washer EPDM Door Boot Bellows Gasket & Outer Spring Clamp

Molded EPDM Front-Load… Copy Part #

Exact OEM part number verified at Pos K551 on WKEX200HBA exploded diagram.

Option #2 • Secondary / Related Part OEM: $128.95-$153.00 / Generic or Surplus OEM: $25-$35

Washer Door Lock & Latch Interlock Switch Assembly

4026EL3007B Copy Part #

Confirmed OEM interlock part numbers for WKEX200HBA.

Repair Cost Too Close to a New Unit? Compare top-rated drop-in stacked washer dryer laundry center replacements & dimensions.
Compare Replacements →
Why This Happens & Safety Warnings
Safety & Disassembly Notes:
  • SHOCK HAZARD: Internal components (pump, valves, motors, control boards) are intentionally not grounded to the sheet-metal chassis and may be electrically live when energized; always disconnect both the 120V washer power cord and the 240V/208V dryer circuit before servicing.
  • TIP & CRUSH HAZARD: Never lay the 311 lb stacked WashTower on its back or side during service, and never mount the unit on a laundry pedestal.
Washer Door Lock Interlock Switch Failure (dE/dE1/dE2) & EPDM Boot Bellows Biofilm or Tear

What triggers it: Repeated thermal/electrical cycling of the PTC bi-metallic door lock, slamming the door or catching garments/zippers at the threshold, or leaving the washer door closed between wet loads.

What wears out inside: PTC wax motor/solenoid contacts inside door lock EBF61315802 fatigue (or dryer catch 4027EL1001A wears), while trapped metal zippers puncture EPDM bellows MDS66290824 or stagnant moisture breeds Aspergillus/Cladosporium mold.

Symptom on machine: Cycle fails to start with dE/dE1/dE2/dE4 error code, water leaks from the front door perimeter, or persistent mildew odor transfers to laundry.

Cross-Compatible Platforms: 200-Series Electric Color Variants (WKEX200HWA White, WKEX200HGA Nature Green, WKEX200HRA Candy Apple Red) are identical in internal hardware to WKEX200HBA.

Other LG WKEX200HBA Problems (8)
1. Quick Test 2. See Fix Parts ↓

Type any brand, model number, error code, or part number...