LG WKEX200HBA: VS or uS (MEMS 3D Vibration Sensor Communication Fault)
⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK
01 // Observed Condition
Washer halts operation due to loss of signal or out-of-range telemetry from the outer-tub 3D MEMS accelerometer.
02 // Non-Invasive Meter / Bench Verification
Perform a 10-minute power-off reset. If VS/uS returns, a technician inspects the wire harness (EAD64545337) connected to the tub-mounted MEMS vibration sensor (EBD48922821) for broken conductors caused by tub oscillation; if harness continuity is intact, replace sensor EBD48922821.
Platform / OEM Cross-Reference: 200-Series Electric Color Variants (WKEX200HWA White, WKEX200HGA Nature Green, WKEX200HRA Candy Apple Red) are identical in internal hardware to WKEX200HBA.