LG WKEX200HBA: FE (Overflow), PE (Pressure Sensor), CE (Motor Over-Current), FF (Frozen), F0 (Lint Filter Out)
⚡ Bench Triage & Meter Telemetry
VISUAL / BENCH CHECK
01 // Observed Condition
FE: water overflow from stuck-open inlet valve; PE: water-level pressure switch fault; CE: Direct Drive motor phase short or IPM over-current; FF: frozen water supply/drain line; F0: dryer lint screen unseated.
02 // Non-Invasive Meter / Bench Verification
For FE: close household water taps immediately to stop flooding and service inlet valves (5221ER1003S / 5220FR2006Z). For F0: firmly seat dryer lint filter ADQ56656403 into the door sill slot. For FF: thaw laundry room above 32F and inspect valves/pump for freeze cracks. For PE/CE: unplug unit for 10 minutes; if persistent, service pressure switch EBF63534901 or stator/Main PCB.
Platform / OEM Cross-Reference: 200-Series Electric Color Variants (WKEX200HWA White, WKEX200HGA Nature Green, WKEX200HRA Candy Apple Red) are identical in internal hardware to WKEX200HBA.